Campbell Hausfeld HM7000 Operating Instructions Manual

Campbell Hausfeld HM7000 Operating Instructions Manual

Campbell hausfeld oilless compressors operating instructions
Table of Contents

Advertisement

Available languages

Available languages

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
warning indicates
a potentially
hazardous situation which, if not avoided,
coulD result in death or serious injury.
caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit.
Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and
parts list (with
missing parts circled) before calling.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2009 Campbell Hausfeld/Scott Fetzer
Oilless Compressors
DO NOT RETURN
STOP!
THE PRODUCT TO
THE RETAILER!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No.
____________________
Serial No.
____________________
Date of purchase _________________
Retain these numbers for future
reference.

General Safety

CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals, including lead, known
to the State of california to cause cancer
and birth defects or other reproductive
harm. wash hands after handling.
You can
create
dust when you cut, sand,
drill or grind materials such
as wood, paint, metal,
concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
wear protective gear.
For parts, product & service information
visit www.chpower.com
HM7000 and HU2000
Breathable Air warning
This compressor/pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1
- 1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
GENERAL SAFETY INFORMATION
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified)
electrician. on a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
IN628800AV 1/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HM7000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Campbell Hausfeld HM7000

  • Page 1: Safety Guidelines

    (with missing parts circled) before calling. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2009 Campbell Hausfeld/Scott Fetzer Oilless Compressors DO NOT RETURN STOP!
  • Page 2: Spraying Precautions

    Disconnect power and depressurize system before servicing air compressor! 9. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
  • Page 3: Installation

    It should be selected using the extension cord Extension cords for 120V/10 Amp Unit Length of Cord (ft) Gauge of Cord HM7000 and HU2000 Terminal Line Load Line Load chart on page 3 as a guide.
  • Page 4: Operation

    Portable Air Compressors Installation (Cont.) shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • Page 5: Maintenance

    HM7000 and HU2000 IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging filter.
  • Page 6 Portable Air Compressors Notes www.chpower.com...
  • Page 7: Troubleshooting Chart

    Air output lower than 1. Broken inlet valves normal 2. Intake filter dirty 3. Connections leaking HM7000 and HU2000 Corrective Action 1. Check for proper use of extension cord (see EXTENSION CORDS, page 3) 2. Plugged in? Check fuse/breaker or motor overload 3.
  • Page 8: Limited Warranty

    8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Portable compressors or components must be delivered or shipped to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Page 9: Directives De Sécurité

    MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2009 Campbell Hausfeld/Scott Fetzer Compresseurs d’Air Sans Huile NE PAS RENVOYER...
  • Page 10: Précautions De Pulvérisation

    Compresseurs D’Air Portatifs Généralités Sur La Sécurité (Suite) 1. Lire attentivement tous les manuels d’instructions pour chaque pièce détachée avant d’esssayer de monter, démonter ou de faire fonctionner votre système. 2. Utiliser des lunettes de sécurité et la protection auditive pendant l’utilisation du modèle.
  • Page 11: Installation Électrique

    38˚C (100˚F). Un espace libre minimum de 45,7 centimètres (18 po) entre le compresseur et un mur est exigé pour éviter le stoppage d’air par des objets. 11 Fr HM7000 et HU2000 borne Chaud Ligne Charge Ligne Charge Ne pas situer la prise d’air du...
  • Page 12: Instructions De Mise À La Terre

    Compresseurs D’Air Portatifs Installation (Suite) b. L’alimentation en tension est normale. c. Les cordons prolongateurs correspondent au moins avec le calibre minimum exigé dans ce manuel d’instructions. d. Le circuit est équipé avec un disjoncteur de 15 ampères ou une fusée à...
  • Page 13: Entretien

    éloigner l'air se déplaçant rapidement du visage. Figure 6 13 Fr HM7000 et HU2000 3. La soupape de sûreté se fermera automatiquement à environ 276 kPa - 345 kPa. Si la soupape ne laisse pas sortir l'air en tirant sur l'anneau, ou si elle ne se ferme pas automatiquement, il FAUT la remplacer.
  • Page 14: Protecteur De Surcharge Thermique

    Compresseurs D’Air Portatifs Entretien (Suite) REMARqUE: Il faut vérifier et nettoyer périodiquement le filtre à air dans le boîtier du filtre du côté de la tête et plus souvent s’il est utilisé sous des conditions très poussièreuses ou lorsqu’il y a beaucoup de brouillard créé...
  • Page 15: Guide De Dépannage

    2. Diminuer l’utilisation d’air; le compresseur n’est pas assez puissant pour la demande 3.Démonter l’assemblage du clapet, nettoyer ou remplacer Serrer 1. Faire réparer le modèle par un agent autorisé 2. Nettoyer ou remplacer le filtre d’admission 3. Serrer les raccordements 15 Fr HM7000 et HU2000...
  • Page 16 2. GARANTIE ACCORDÉE PAR (GARANT): Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR): L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE: N’importe quel compresseur d’air Campbell Hausfeld.
  • Page 17: Medidas De Seguridad

    Si el compresor se utiliza para producir aire respirable SIN haberle instalado el sistema de seguridad y alarma, todas la garantías se anularán y la compañía Campbell Hausfeld no asumirá NINGUNA responsabilidad por pérdidas, heridas personales o daños. INFORMACIONES GENERALES DE...
  • Page 18 Compresores de Aire Portátiles Generales de Seguridad Continuación 1. Lea con cuidado todos los manuales incluídos con este producto antes de tratar de ensamblar, desman-telar o utilizar el sistema. 2. Siempre use anteojos de seguridad y protéjase los oídos para operar el cabezal o el compresor.
  • Page 19: Instalación

    1. Inserte los extremos del mango en los soportes en forma de tubo en el tanque. Tanque Mango Pernos Figura 3 - Ensamble del mango 19 Sp HM7000 y HU2000 Terminal Con tensión Línea Tensión Línea Tensión 2. Alinee los agujeros de los tornillos.
  • Page 20 Compresores de Aire Portátiles Instalación (Continuación) 2. Use fusibles de acción retardada tipo T o un cortacircuito. Si no conecta los cables adecuadamente podría haber cortocircuitos, incendios,sobrecalen-tamiento etc. Todas las conexiones eléctricas y el alambrano deberán ser llevados a cabo por un electricista profesional.
  • Page 21: Mantenimiento

    (consulte Funcionamiento). 21 Sp HM7000 y HU2000 2. Usando gafas de protección, tire del anillo de la válvula de seguridad (vea las Figura 6) para liberar la presión del tanque del compresor. Use su otra mano para desviar el aire que se mueve a gran velocidad y evitar que le dé...
  • Page 22 Compresores de Aire Portátiles Mantenimiento (Continuación) 4. Apague el compresor (póngalo en OFF ) y limpie completamente el motor, tanque, líneas de aire y las aletas de enfriamiento del cabezal. Figura 7 NOTA: Es necesario chequear y limpiar con frecuencia el filtro de aire dentro de la cubierta del filtro del lado del cabezal, y con todavía más frecuencia si se usa en condiciones de mucho...
  • Page 23 3. Desmantele la válvula de chequeo, límpiela o reemplácela Apriete los pernos 1. Un técnico autorizado de servicio debe repararlo 2. Limpie o reemplace el filtro de entrada 3. Apriete las conecciones 23 Sp HM7000 y HU2000...
  • Page 24 A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto. B. Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador.

This manual is also suitable for:

Hu2000

Table of Contents

Save PDF