Your new Telawny SPT power tool will more than satisfy your expectations. It has been manufactured under stringent Trelawny SPT Quality Standards to meet superior performance criteria. You will find your new tool easy and safe to operate, and, with proper care, it will give you many years of dependable service.
Page 4
Appendix 1 - Hazardous Area Certification The VL203/223 & VL303 Needle Scalers are certified compliant to the ATEX Directive (2014/34/EU) for safe use within a hazardous area and has been assessed so by TRaC (Notified Body 0891). This product conforms to the Standards: EN 13463-1:2009 EN 13463-5:2011 EN ISO 4414:2010...
This tool must not be used in a fixture. ingested. Safety A Trelawny ATEX rated, 30 litre air operated vacuum system with a HEPA filter, is available as a separate Always, read instructions first before use. vacuum or as a Kit containing either a VL203, VL223...
Page 6
The compressor should be able to supply a minimum Handled correctly the VL203Ex Needle Scaler will work of 3.77 L/s (8cfm) of free air not displaced as quoted quickly and efficiently. by some compressor manufactures, this will give 3cfm of headroom, so that the compressor isn’t continually...
Clean all deposits from the recommended lubricants. the outside of the tool. Service kits are available, see parts section. ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
Page 8
Remove the ball retaining O’Ring (18) from its groove just inside the bore of the stem using a suitable pointed implement. Remove the ball from the bore, replace and refit new O’Ring into groove. ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
Page 9
■ Locate Throttle Lever (7) in the Valve Body (6) using a 3 mm punch to align holes. ■ Secure by inserting Spring Pin (8). ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
3mm Needle Holder (fitted as standard) 403.1309 Needle set (1 x set Beryllium Copper) 712.2003 Front Spring 620.2003 Front Tube Insert 620.2003A Front Tube Spacer 622.2030 Front Tube 809.3005 Cylinder Stem Reaction Ring 610.2003 Anvil ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
Check for and remove the remains of the ball, possibly in an 6mm plastic ball worn out. exhaust hole of cylinder and renew 6mm plastic ball. Tool stopped working. Valve pin broken. Replace valve pin and 6mm plastic ball. ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
Page 13
Because of various factors, the vibration from this range of tools may be between 3.26 m/s2 – 4.56m/s2. The vibration is dependent on the task, the operators grip, and feed force employed. ATEX Certified VL203Ex Needle Scaler Operation and Maintenance 735.3002X...
Page 14
Any unauthorised use or copying of the contents or part thereof is prohibited. This applies to trademarks, model denominations, part numbers and drawings. Use only genuine Trelawny spares. The use of non-Trelawny spare parts will invalidate the ATEX certification and also the warranty. ATEX Certified VL203Ex Needle Scaler Operation and Maintenance...
Need help?
Do you have a question about the VL203Ex and is the answer not in the manual?
Questions and answers