This repair will require removal of the unit from it's mounting hardware and repair made on a clean work surface. Refer to your
owners manual to reverse the wiring, mounting, and assembly process. READ AND FOLLOW ALL SAFETY, INSTALLATION AND
OPERATION INSTRUCTIONS AND WARNINGS CONTAINED IN THESE INSTRUCTIONS AND THE OWNERS MANUAL. If you
have any questions or do not understand an instruction, contact a trained service technician. Or call 800-354-3643.
!
WARNING
BE SURE ELECTRICAL POWER HAS BEEN DISCONNECTED FROM THE INPUT POWER LINES PRIOR TO REMOVING THE MOTOR COVER.
WARNING
!
ANY AND ALL REPAIRS MADE TO THIS UNIT MUST BE PERFORMED WITH THE DOOR DISCONNECTED FROM THE OPENER AND IN THE
CLOSED POSITION.
1. Before pulling emergency release cord, make certain
people and objects are clear of door opening. Pull
emergency release cord on carriage to disengage
opener to close door if necessary. (If unable to lower
door using opener, use extreme caution manually
closing door.
2. Remove power from opener.
3. Remove lens cover(s) by pressing side tabs inward
and remove light bulb(s). FIG. 1.
4. Remove wall control and Safe-T-Beam® wires from
terminal block located on back of opener FIG. 1. Use
small common screwdriver to press in on orange
locking clips while gently pulling wires from block.
Mark wires to help facilitate replacement.
5. Remove door arm clevis pin and cotter-hairpin to disconnect operator from
door. FIG. 2.
6. Remove opener from mounting brackets and hardware and set on a clean
work surface.
7. Remove 3 bolts from rail assembly and set rail aside. FIG. 1.
8. Remove 2 screws securing control board to powerhead cover. FIG. 3.
FIG. 2.
clevis pin & cotter pin
39431502927
Motor Replacement
Carriage
FIG. 1.
Locking
Clips
6
Photocell
FIG. 3.
Terminal
Holes
5
4
3
2
1
Wall
Photocell
Control
01/2016

Advertisement

loading

Summary of Contents for Genie 600 Series

  • Page 1 Motor Replacement This repair will require removal of the unit from it’s mounting hardware and repair made on a clean work surface. Refer to your owners manual to reverse the wiring, mounting, and assembly process. READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS AND WARNINGS CONTAINED IN THESE INSTRUCTIONS AND THE OWNERS MANUAL.