9. Lower the control board assembly to access control board and wire harnesses.
10. Note locations and unplug wire harnesses from control board. FIG. 5.
OPTO, LIGHTS, MOTOR, TRANSFORMER HARNESSES
11. Remove 4 screws securing cover and remove cover. FIG. 6.
12. Remove 3 screws at top of powerhead to remove motor. FIG. 7.
13. Install replacement motor in reverse order.
14. Replace cover with 4 screws.
15. Replace control board harnesses.
Note: Be certain to install all harnesses in the correct position.
16. Replace control board assembly and secure with 2 screws.
17. Install rail assembly to powerhead with 3 bolts.
18. Reinstall powerhead and rail assembly to ceiling and door. Steps 5,4,3.
19. Install light bulb(s) and lens cover(s).
20. Apply power to opener.
21. Test unit fully to ensure travel limits, remote controls and all safety features work correctly. Refer to your owners
manual and/or assembly poster.
FIG.4.
FIG.6.
Download manuals/installation posters at www.GenieCompany.com
OPTO
FIG.5.
Parts removed for clarity
FIG.7.
Light(s)
Motor
Transformer