Fxs Supervision Table - ADC ICX-250 User Manual

Adc hub/switch model icx-250 user manual
Table of Contents

Advertisement

Switches

FXS Supervision Table

(Mode)
FXS
FXS-DN
FXS-DN-WINK
TR-08
Legend: (e.g. S1 position 5 = 01001 means Mode = FXS-DN / Type = LS-fd)
Issue 1, September 1998
© 1998, ADC Telecommunications, Inc.
!!ATTENTION!!
switches will result in all FXS calls on the affected 12
FXS line group to be reset to the idle state each time a
DIP switch setting is changed. This means any active
calls in that FXS line group will be dropped.
1, 2
000
001
00
LS
LS-fd
01
LS
LS-fd
10
LS
LS-fd
11
SP
---
LS = Loop Start
LS-fd = Loop Start-Forward Disconnect
GS = Ground Start
GSa = Ground Start Automatic
GSi = Ground Start Immediate
SP = Single Party
UVG = Universal Voice Grade
UVGa = Universal Voice Grade Automatic
Configuring the ICX-250
Changing the Supervision type
3, 4, 5 (Type)
100
101
GS
GSa
GS
GSa
GS
GSa
UVG
UVGa
25
110
GSi
GSi
GSi
---
ADCP-62-023

Advertisement

Table of Contents
loading

Table of Contents