Before handling this product, please read through and follow the instructions and
precautions in the instruction manual of the IV0620C.
This operation manual is an excerpt from the descriptions and instructions in the instruction
manual of the IV0620C, which include the setup procedures during the use of the product,
the functions of the basic operating components, descriptions on the indicator and menu
displays, and safety precautions.
Intended use
This instrument is intended for inspecting and observing the interior of machinery, equipment,
materials, and other objects, without damaging the object being inspected.
Setting up the IV0620C
This product can be set up easily for inspection to be performed immediately.
Simply follow the four steps below to complete the setup.
1. Remove components from the case
Remove the components in the following
sequence: insertion unit → main unit.
2. Preparing the power supply
• Using battery: Check to ensure that the battery is charged, followed by setting it to the main unit.
A Push down the battery door lock to open the battery door.
B Load the battery according to the direction indicated on the battery terminal while paying
attention to the orientation of the battery.
C Press the battery from above until a "click" sound is heard. After the battery is correctly loaded,
close the battery door.
Insertion Unit
Main Unit
Industrial Endoscope
1

Advertisement

Table of Contents
loading

Summary of Contents for Olympus IV0620C

  • Page 1 This operation manual is an excerpt from the descriptions and instructions in the instruction manual of the IV0620C, which include the setup procedures during the use of the product, the functions of the basic operating components, descriptions on the indicator and menu displays, and safety precautions.
  • Page 2: Turning On Power

    If the tip protection hood is loose, attach it properly according to “6.2 Replacing the Tip Protection Hood” in the instruction manual of IV0620C. The tip protection hood is an expendable item. Replace the tip protection hood when it is worn out or deformed.
  • Page 3: Part Names And Functions

    If you are using the SD card media for the first time, format it with the main unit before you start recording. For more details on the procedure, please refer to the instruction manual of the IV0620C. Record still images 1.
  • Page 4: Menu Screen Display

    LCD monitor nomenclature Movie recording indicator Battery indicator Folder name Number of images that can be recorded Freeze indicator Folder Jump Button [MENU] button Temperature indicator [VIEW] button Brightness setting button, brightness level [THUMBNAIL] button Zoom setting button, [LIGHT] button zoom level Logo Date/Time...
  • Page 5 Using the live screen/freeze screen Menu Available settings TITLE INPUT Title input A title can be displayed in the live screen and in registered images. Input can be up to 30 characters. WHITE White balance adjustment (Live screen only) BALANCE Specifies whether to perform white balance.
  • Page 6 Menu Available settings MEDIA SD card formatting (initialization) FORMAT DATE TIME Date and time settings TOUCH Adjusts the response position when you touch the touch panel. SCREEN Perform adjustments accordingly when the response position is out of ADJUST alignment when you touch the screen. LANGUAGE Display language selection Specifies the language used for menus and messages.
  • Page 7 Inputting a title Input text from the on-screen keyboard Touch the character selection button to select an input mode. Touch the character buttons. Touch [EXECUTE]. Selecting a preset title for input Touch [PRESET]. Touch the corresponding preset title in the list. Touch [EXECUTE].
  • Page 8: General Safety Precautions

    This instrument does not contain any user serviceable parts. Do not disassemble, modify or attempt to repair. User injury and/or equipment damage can result. Contact Olympus for all repair and servicing. Olympus is not liable for any accident or instrument damage that occurs as a result of repairs attempted by non-Olympus personnel.
  • Page 9 • Pay attention not to trip over the power cord or cables of the insertion tube. • Use only a power cord and AC adapter specified by Olympus. Doing so may result in fuming, fire, or electric shock.
  • Page 10 • Do not use components other than the insertion tube in the rain or in water, and do not wash them with running water or a wet object. This instrument is not waterproof. Exposure to water may result in electric shock. It must not be used or stored in water.
  • Page 11: Battery Precautions

    Battery precautions Should you experience any problems when using the instrument with batteries, contact Olympus. Observe the precautions described below when handling the battery. Otherwise, battery fluid leak, excessive heat generation, smoke, battery burst, electric shock and/or burns may result.
  • Page 12 • If you are having problems removing the battery from the instrument, do not apply undue force. Contact Olympus. • When carrying the battery onto an airplane, please contact the airline beforehand. • When changing the battery, do not remove and insert the battery rapidly and repeatedly.