1.1.3

Power Led

LED Flash Cadence
9 flashes, pause
8 flashes, pause
7 flashes, pause
6 flashes, pause
5 flashes, pause
3 flashes, pause
2 flashes, pause
1 flash, pause
LED ON continuously
Table 1: Interpretations of LED flash cadence (TX LED Off)
LED Flash Cadence
9 flashes, pause
8 flashes, pause
7 flashes, pause
6 flashes, pause
4 flashes, pause
3 flashes, pause
2 flashes, pause
1 flash, pause
LED ON continuously
Table 2: Interpretations of LED flash cadence (TX LED On)
1.1.3
POWER LED
The PWR LED shows that the dc supply is connected to the receiver and that the
microprocessor is not being held in a RESET state.
1.1.4

TX LED

The TX LED illuminates when the transmitter is keyed. It will not illuminate (and an
ALARM cadence will be shown) if the synthesizer becomes unlocked, or the output
amplifier supply is interrupted by the microprocessor.
1.1.5

ALARM LED

The Alarm LED can indicate several fault conditions if they are detected by the self test
program. The alarm indicator shows the highest priority fault present. See Tables 1
and 2.
Page 6
Fault Condition
External PA failure
Low dc supply on External PA
External PA Over Current Condition
External PA Over Temperature
Synthesizer unlocked
Unable to communicate with External PA
The current channel is not programmed or the frequency
is out of range.
Low dc supply voltage
Transmitter timed out
Fault Condition
External PA failure (if PTT is pressed)
Low dc supply on External PA (if PTT is pressed)
External PA Over Current Condition(if PTT is pressed)
External PA Over Temperature(if PTT is pressed)
Either PLL is near operational limit
Forward Power Out of Range(if PTT is not pressed)
Reverse Power ratio exceeded.
Low dc supply voltage
Transmitter timed out
1 OPERATING INSTRUCTIONS