Yamaha Tyros3 Service Manual page 111

Monitor speaker
Hide thumbs Also See for Tyros3:
Table of Contents

Advertisement

056:Effect RAM Check2
TG1 NG
TG2 NG
Supplement:
TG1 indicates Effect RAM of SWP51B Master (DM: IC505)
and TG2 indicates Effect RAM of SWP51B Slave (DM: IC506).
Circuit
Error Indications
Board Location
TG1 NG
DM
TG2 NG
DM
Test 57 to 62
Factory Inspection only.
Test 63
Function: Factory Set
Description:
Restores the Tyros 3 to the factory initial setup.
(Sets the initial data to the Flash ROM.)
Displayed Message:
063:Factory Set
INITIAL SETTING
Setting at the time of factory shipping.
• MASTER VOLUME:
• INPUT VOLUME:
• MODURATION WHEEL:
• LINE IN/MIC TRIM VOLUME:
• AUX IN/LOOP RETURN TRIM VOLUME: MIN
• SLIDER VOLUME:
In case of NG
Name in Circuit Diagram
IC508
WORK RAM 64 M SDRAM
IC509
WORK RAM 64 M SDRAM
Selected screen
MIN
MIN
MIN (toward you)
MAX
MAX (top side)
063:Factory Set
OK
Supplement:
In this stage, the fl ag for initialization is raised only and
initialization will be executed when the power is turned on
next time.
Caution
Don't turn off the power until the main screen is indicated
after executing the "Factory Set".
Test 64
Function: Exiting test mode
Description:
Quits the test mode and restarts. (Restarting should be
conducted automatically. Check if the restarting is conducted.)
Displayed Message:
064:Test Exit
Supplement:
Caution
Don't turn off the power until the main screen is indicated
after executing the "Exiting test mode".
Tyros3
During execution
Selected screen
111

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trs-ms02