Emerson Numatics DeviceLogix G2-2 Series Quick Start Manual page 5

Table of Contents

Advertisement

Available languages

Available languages

5) I/O Mapping Example
Example:
Assumed Settings
- Single Z-Boards
used with single solenoid
TM
valves
- Double Z-Boards
used with double solenoid
TM
valves
For simplicity, two mapping formats are given to
match appropriate software tools (i.e. DeviceLogix is
for the logic editor function within RSNetworx
DeviceNet).
Discrete I/O Configuration
Pos
Module Type
Part No.
No.
1
MCM
239-1384
8O Sourcing
2
239-1315
(PNP)
16O Sourcing
3
239-1319
(PNP)
4I Sinking
4
239-1304
(NPN)
8I Sinking
5
239-1308
(NPN)
Manifold I/O Configuration
Outputs and Mapping Location
DeviceNet
Byte 0, Bits 0-7
-Valve Outputs = 12
Byte 1, Bits 0-3
Byte 1, Bits 4-7
-Allocated Unused
Bytes 2 - 3, Bits
Valve Outputs = 20
Bytes 4,5 & 6
-Discrete Outputs = 24
Bits 0-7
Total Outputs = 56
Inputs and Mapping Location
DeviceNet
Byte 6, Bits 0-3
-Discrete Inputs = 12
Byte 7, Bits 0-7
-Allocated and
Byte 6, Bits 4-7
Reserved Inputs = 4
Total Inputs = 16
G2-2 Series DeviceLogix Quick Start Manual
for
TM
Rx
Tx
Bytes
--
--
1
1
1
2
1
0
1
0
DeviceLogix
Bits 0-11
Bits 12-31
0-7
Bits 32-55
DeviceLogix
Bits0-3
and 8-15
Bits 4-7
3835054 TDG22DLQS3-0
Subject to change without notice
www.numatics.com/fieldbus
When the 12 End
When the 14 End
Solenoid is
energized, the 2 port
energized, the 4 port
is pressurized.
is pressurized.
1/07
Solenoid is
Page 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Numatics DeviceLogix G2-2 Series and is the answer not in the manual?