Lenovo DM120S Installation And Cabling Manual page 7

Hide thumbs Also See for DM120S:
Table of Contents

Advertisement

The following illustration shows how the drives are numbered from 0 to 11 in each drive drawer
within the shelf. In a shelf containing 30 drives, slots 0, 1, 3, 6, 9, and 10 must contain drives.
a.
Reinstall any power supplies and IOMs you removed prior to installing your disk shelf into the
rack.
b.
Open the top drawer of the shelf.
c.
Raise the cam handle on the drive to vertical.
d.
Align the two raised buttons on each side of the drive carrier with the matching gap in the drive
channel on the drive drawer.
1
Raised button on the right side of the drive carrier
e.
Lower the drive straight down, and then rotate the cam handle down until the drive snaps into
place under the orange release latch.
f.
Repeat the previous substeps for each drive in the drawer.You must be sure that slots 0, 3, 6,
and 9 in each drawer contain drives.
g.
Carefully push the drive drawer back into the enclosure.
h.
Close the drive drawer by pushing both levers towards the center.
Chapter 1
.
Installing and cabling disk shelves with IOM12 modules for a new system installation
Attention: Possible loss of data access – Never
slam the drawer shut. Push the drawer in slowly to
avoid jarring the drawer and causing damage to the
storage array.