Lenovo DM120S Installation And Cabling Manual page 56

Hide thumbs Also See for DM120S:
Table of Contents

Advertisement

Step 1.
Cable port pair 1a/2b on each controller to stack 1:
This is the multipathed cabling for stack 1.
a.
Cable controller 1 port 1a to stack 1, first shelf IOM A port 1.
b.
Cable controller 2 port 1a to stack 1, first shelf IOM B port 1.
c.
Cable controller 1 port 2b to stack 1, last shelf IOM B port 3.
d.
Cable controller 2 port 2b to stack 1, last shelf IOM A port 3.
Step 2.
Cable port pair 2a/1d on each controller to stack 1:
This is the quad-pathed cabling for stack 1. Once completed, stack 1 has quad-pathed
connectivity to each controller.
a.
Cable controller 1 port 2a to stack 1, first shelf IOM A port 2.
b.
Cable controller 2 port 2a to stack 1, first shelf IOM B port 2.
c.
Cable controller 1 port 1d to stack 1, last shelf IOM B port 4.
d.
Cable controller 2 port 1d to stack 1, last shelf IOM A port 4.
Step 3.
Cable port pair 1c/2d on each controller to stack 2:
This is the multipathed cabling for stack 2.
a.
Cable controller 1 port 1c to stack 2, first shelf IOM A port 1.
b.
Cable controller 2 port 1c to stack 2, first shelf IOM B port 1.
c.
Cable controller 1 port 2d to stack 2, last shelf IOM B port 3.
d.
Cable controller 2 port 2d to stack 2, last shelf IOM A port 3.
Step 4.
Cable port pair 2c/1b on each controller to stack 2:
52