Plumb the solar feed and return lines between the filter and the heater. Install a three-port valve
9
at the feed line. Use a solar valve (model SOL-2T), to allow automatic draining of the panels.
A solar booster pump should be used when the distance to the panels exceed 200 ft., or the
10
panels are elevated higher than 25 ft.
Glazed solar panels require a drain valve (model HW-5B) to allow draining of the panels. This
11
prevents damage from overheating water. Install a drain valve at the solar feed line and connect
to the pool fill line.
SCG systems only: IntelliChlor
12
check valve at the heater output. Refer to IntelliChlor SCG User's Guide (P/N 520589) for

plumbing requirements.

Equipment Location

All equipment, with the exception of the spa-side remote, must be located at least 10 ft. from the