Options Summary
Start Control
Temperature
Temperature Limit Value of FAN Start Control
Full Speed
Temperature
Temperature Limit Value of FAN Full Speed
PWM Slope
Slope PWM value/Degree C for FAN Speed Control Range: [1-15]
System Fan Control
Enable/ Disable System Fan Control
Enabled: FAN operates in accordance with user settings
Disabled: FAN always operates at full speed
FAN Control Mode
Manual Mode: Depends on PWM Duty
Automatic Mode: FAN Speed depends on System Temperature
Spin PWM
The PWM Duty of FAN Spin Range: [0 - 255]
Off Control
Temperature
Temperature Limit Value of Fan Off
NOTE: Some fans have a minimum speed even if the PWM value is 0
Start Control
Temperature
Temperature Limit Value of FAN Start Control
Full Speed
Temperature
Temperature Limit Value of FAN Full Speed
PWM Slope
Slope PWM value/Degree C for FAN Speed Control Range: [1-15]
Chapter 3 – AMI BIOS Setup
85
99
1
Disabled
Enabled
Manual Mode
Automatic Mode
40
25
80
99
1
Optimal Default, Failsafe Default
Optimal Default, Failsafe Default
42