Muffler Installation

1. Insert the rubber coupling on the vacuum air exhausts.
2. Using a Phillips screwdriver, tighten the clamp collar to ensure ad-
equate sealing.
3. Insert the 90° elbow into the rubber coupling, and tighten then clamp
collar as per instructions in step 2.
4. Apply ABS glue to the 90° elbow and insert muffler.
5. For H110, repeat steps 1 to 4 to install second muffler turned down.
A
D

Electric Connections

There should be an electric outlet within 1 meter (3 feet) of your central
vacuum unit. Once the appliance is installed in a suitable location, con-
nect your central unit to an electric outlet on an dedicated* grounded
circuit. Do not use extension cords or modify the length of your vacuum
cleaner's power cord.
Dedicated* grounded circuit
• North America
120 V / 240 V All models: 15A
Your central vacuum cleaner has a thermal safety device or a circuit break-
er to protect against any over voltage or electrical defect. If that protection
should fail, contact your authorized service center.
*Please reserve a circuit breaker dedicated only to the connections for your
central vacuum.
If you find that installing your vacuum cleaner is too difficult, ask your service
center to install it for you. When in doubt, it is better to have the work done by a
professional and ensure that the unit is properly installed. Any installation that
does not comply with the specified norms could alter or invalidate the warranty.
(Optional)
C
B
Glue not included
Installation
A. Rubber coupling
A
B. 90° elbow
C. Muffler
D. Air Exhaust