Setting The Controller Type - ECKELMANN UA 410 L Series Operating Instruction

Temperature data logging controller
Table of Contents

Advertisement

6.2.2 Setting the controller type

Caution: data loss! All parameters are reset to their factory settings if the controller type is changed or
due to a first start (see chapter
Setting of the controller type
The required controller type can be set via the DIP switch S3 by adjusting the coding switches 1..9 with a thin
screwdriver (D = 2 mm) through a hole in the case cover:
Depending on the now set controller type, the respective functionalities are then displayed or hidden in the
menu of the controller. 8 controller types are available for the definition of the basic controller behaviour, see
chapter
Controller
type.
Warning - hazardous electrical voltage!Danger of electric shock! DIP switch S3 must be changed
in voltage-free state only. Settings become effective on the case controller until the controller is briefly
switched off and back on!
Firmware V3.00
Erstanlauf - Regler auf Werkseinstellungen
05.08.2019
zurücksetzen)!
39/100