Differentiation is made between two operating modes:
Archiving sensors of UA 410 L
If the parameter EU-Archiv CAN in the temperature recording
controller is set to its own CAN address, the temperatures and
statuses of the controller are recorded in the system centre / store
computer.
The EU Archive Zone parameter defines the zone of the sensor
recorded by the Temperature Data Logging
Controller.
Values 3 to 10 of the EU Archive Zone parameter are to be used only for recording in conjunction with
the Temperature Data Logging Controller itself. Only values 1 or 2 may be used for recording in
conjunction with a case/EU archiving must also be active on the System Centre / Store Computer in
order to commence recording (see System Centre / Store Computer operating instruction).
It must be ensured that both the system centre / store computer as well as the temperature recording
controller UA 410 L have a software version that supports recording controller operation according to
EU regulation DIN EN 12830 (see description in the operating manuals of the respective controllers).
The Store Computer must have sufficient memory (2, 6 or 16 MB) for data recording.
Reading out archived data
The recorded data for the system centre / store computer is read out as follows:
CI 4x00: see menu 2-6 "EU archives".
CI 3x00: see menu 3 "Archive".
Furthermore, it is possible to retrieve the archived temperatures from the system centre / store computer using
the PC software LDSWin and present them in graphic form (see operating manuals of the system centre / store
computer and of the PC software LDSWin).
Firmware V3.00
Archiving sensors of external case controller
(complies with DIN EN 12830)
If the parameter EU-Archiv CAN is set to the CAN address of
another case controller (UA 400 / UA 400 E), then its statuses are
recorded together with the temperature of the
UA 410 L.
The EU Archive Zone parameter defines the zone of the
UA 400 / UA 410 E controller, for which the sensors recorded by
the UA 410 L is used.