Summary of Contents for Klimaire KIWQ Series

  • Page 1 KIWQ/KOIQ Manual Mark of Superior Quality IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. For more information please visit www.klimaire.com IMIQ 20-07...
  • Page 2: Table Of Contents

    INSTALLATION PLACE ..................22 INSTALLATION ......................23 MAINTENANCE ..................... 36 TROUBLESHOOTING ..................... 37 GENERAL NOTES ....................38 This document, illustration, data,information herein contains are the property of Klimaire products inc. and can't be duplicated, modified or reproduced by any means.
  • Page 3: Safety Rules And Recommendations For The Installer

    Safety Precautions Read Safety Precautions Before Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. This symbol indicates that ignoring instructions may cause moderate injury to person, or damage to your unit or other property.
  • Page 4 Safety Precautions This symbol indicates that ignoring instructions may cause death or serious injury. WARNING 1. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire. 2. Contact an authorized service technician for repair or maintenance of this unit. 3.
  • Page 5: Accessories

    Accessories The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. Name Shape Quantity...
  • Page 6: Main Parts

    Air Conditioning Unit - Main Parts Wall Mounting Plate Front Panel Louver Drainage Pipe Optional Healthy Filter (On Front of Main Filter) Signal Cable Quick Connect Refrigerant Piping Remote Control Remote Control Holder(some units) NOTE ON ILLUSTRATIONS Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different.
  • Page 7: Names Of The Parts

    NAMES OF THE PARTS INDOOR UNIT INDOOR UNIT Description Front panel Air filter Optional filter (if installed) (optional) LED Display Signal receiver Terminal block cover Ionizer generator (if installed) Deflectors Emergency button Indoor unit rating label ( Stick position optional Airflow direction flaps Remote control Remote control holder...
  • Page 8: Indoor Unit Display

    INDOOR UNIT DISPLAY Function This symbol appears when the unit power is on POWER SLEEP mode SLEEP (1) Lights up during Timer operation when the air conditioner is operational Temperature display (if present) (2)Displays the malfunction code when fault /Error code occurs.
  • Page 9: Emergency Function & Auto-Restart Function

    EMERGENCY FUNCTION & AUTO-RESTART FUNCTION If the remote controller fails to work or maintenance necessary, proceed as following: front panel Open and lift the front panel up to an angle to reach the emergency button. For heating model, press the emergency button at first time, the unit will operate in COOL mode.
  • Page 10: Remote Control

    REMOTE CONTROL The display and some functions of the remote control may vary according to the model. The shape and position of buttons and indicators may vary according to the model, but their function is the same. The unit confirms the correct reception of each button with a beep.
  • Page 11 REMOTE CONTROL ( NOTE: SEE ILLUSTRATION ON PAGE 8 ) Button Function To turn on/off the air conditioner . To decrease temperature, time setting or choose the function. To increase temperature, time setting or choose the function. To select the mode of operation(AUTO, COOL, DRY, FAN, HEAT). MODE To activate/deactivate the ECO function .
  • Page 12 REMOTE CONTROL Remote control DISPLAY Meaning of symbols on the liquid crystal display Symbols Meaning Battery indicator Auto Mode function indicator Cooling Mode indicator Dry Mode indicator Fan only Mode indicator Heating Mode indicator ECO Mode indicator Timer indicator Temperature indicator Fan speed indicator: Auto/low/mid/high Mute function indicator SUPER function indicator...
  • Page 13 REMOTE CONTROL Replacement of Batteries Remove the battery cover plate from the rear of the remote control, by sliding it in the direction of the arrow. nstall the batteries according the direction (+and -)shown on the Remote Control. Reinstall the battery cover by sliding it into place. Use 2 pieces LRO3 AAA (1.5V) batteries.
  • Page 14: Operating Instructions

    OPERATING INSTRUCTIONS Filter The air sucked by the fan enters from the grill and passes through the filter, then it is cooled/dehumidified Heat or heated through the heat exchanger. The direction of the air outlet is motorized up and down by flaps, and manually moved right and left by the vertical deflectors, for some models, the vertical deflectors could be controlled by motor as well.
  • Page 15 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS COOLING MODE The cooling function allows the air condit- COOL ioner to cool the room and at the same time reduces Air humidity. To activate the cooling function ( COOL ) , press the MODE button until the symbol appears on the display.
  • Page 16 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS DRY MODE This function reduces the humidity of the air to make the room more comfortable. To set the DRY mode , Press MODE until appears in the display. An automatic function of pre-setting is activated. FAN MODE(Not FAN button) Fan mode, air ventilation only.
  • Page 17 OPERATING INSTRUCTIONS Attention: Before starting up or operating the air conditioner for the first time, confirm the service valves are open. DISPLAY function (Indoor display) Switch ON/OFF the LED display on DISPLAY panel. Press DISPLAY button to switch off the LED display on the panel.
  • Page 18 OPERATING INSTRUCTIONS ECO function In this mode the appliance automatically sets the operation to save energy. Press the ECO button, the appears on the display, and the appliance will run in ECO mode. Press again to cancel it.. NOTE: The ECO function is available in both COOLING and HEATING modes.
  • Page 19 OPERATING INSTRUCTIONS TIMER function ---- TIMER ON To automatic switch on the appliance. TIMER When the unit is switch-off, you can set the TIMER ON. To set the time of automatic switch-on, as below: 1. Confirm the appliance is OFF. And press the TIMER button at first time to set the needed mode and fan speed, the will appear on the display.
  • Page 20 OPERATING INSTRUCTIONS I FEEL function I FEEL Press I FEEL button to active the function, the will appear on the remote display. Do it again to deactivate this function. This function enables the remote control to measure the temperature at its current location, and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort.
  • Page 21 OPERATING INSTRUCTIONS 46° F heating function 1. Press AH button to active this function, and AH will appears on the remote display. Do it again to deactivate this function. 2. If the unit is standby, this function will automatically start the heating mode when the room temperature is equal or lower than 8 (46 ), and it will return to standby if the temperature reaches 9 (48 ).
  • Page 22: Installation Place

    INSTALLATION MANUAL---Selecting the Installation Place INDOOR UNIT Install the indoor unit level on a strong wall that is not Mounting plate 6 or subject to vibrations. 150mm 6 or 6 or The inlet and outlet ports should not be obstructed: the 150mm 150mm air should be able to blow all over the room.
  • Page 23: Installation

    INSTALLATION MANUAL---Installation of the Indoor unit Check the top of indoor unit carton box, there is a quick- installation paper board, it is a guideline to find the screw and hole drilling position quickly. Before starting installation, decide on the position of the indoor and outdoor units, taking into account the minim- 2.75 inch um space required around the units.
  • Page 24 INSTALLATION MANUAL - Indoor Unit installation Mounting plate Refrigerant piping setting position 6 or 6 or The copper pipe should be set through the wall to outside 150mm 150mm 6 or when installing the indoor unit, for quick-connecting 150mm product. Run the piping in the direction of the wall hole, and put the drain pipe at the bottom, then bind the copper pipes and the drain pipe and the power cables together with...
  • Page 25 INSTALLATION MANUAL - Indoor Unit installation Connections to the indoor unit 1. Remove the indoor unit pipe cap (check that there is no debris inside). Smoothly align the female quick connector to the male one which is fixed with indoor unit by hand at first, and fasten smoothly.
  • Page 26 INSTALLATION MANUAL - Indoor Unit installation INSTALLATION OF THE INDOOR UNIT Fig. 23. After having connected the pipe according to the instruc- tions, install the connection cable plugs firmly. Covered by vinyl tape Now install the plastic drain extension pipe. After connection, wrap the pipes, cable and drain pipe with the insulating tape.
  • Page 27 INSTALLATION MANUAL - Outdoor Unit installation If the drain joint comes with a rubber seal Seal (see Fig. 24.1), do the following: 1. Fit the rubber seal on the end of the drain joint Seal that will connect to the outdoor unit. 2.
  • Page 28 INSTALLATION MANUAL--- Refrigerant Piping Connection Connecting the refrigerant pipe CONNECTING THE PIPES to outdoor unit 3. Remove the plastic seals from the outdoor unit Ensure the pipe connectors are the valve and male quick connectors until when same to the indoor´s and outdoor´s you immediately install them.
  • Page 29 INSTALLATION MANUAL - Outdoor Unit installation Two open end spanners must be used in order not to twist and kink the copper pipe. Important! Since the couplings work with tapping rings, it may leak if you undo and reconnect the couplings. This will also void the warranty Important! The conical ring on the valve has an imoportant sealing function together with the sealing seat in the caps.
  • Page 30 INSTALLATION MANUAL - Outdoor Unit installation Proper torque chart Newton meter(N-m) Pound-force(1bf-ft) Kg-force meter(kgf-m) Coupling dimension ( 6.35)9.5mm dash size 11.8 11.8 ( 9.52)12.7mm dash size ( 12.7)19mm dash size 13.3 ( 16)25.4mm dash size 14.8 Fig.26.1 Note: Leakage check. After completing the installation, check all the connecting are sealed correctly using leak detection spray or soap suds.
  • Page 31 Electrical and Gas Leak Checks INSTALLATION MANUAL - WARNING - RISK OF Electrical Safety Checks ELECTRIC SHOCK After installation, confirm that all electrical wiring is installed in accordance with local and national ALL WIRING MUST COMPLY WITH LOCAL regulations, and according to the Installation Manual. AND NATIONAL ELECTRICAL CODES, AND MUST BE INSTALLED BY A LICENSED BEFORE TEST RUN...
  • Page 32 Test Run INSTALLATION MANUAL - Attention: Before starting up or operating the air conditioner for the first time, confirm the service valves are open. List of Checks to Perform PASS/FAIL Before Test Run No electrical leakage Only perform test run after you have completed the following steps: Unit is properly grounded Electrical Safety Checks - Confirm that...
  • Page 33 INSTALLATION MANUAL - Final stages 1. Wind insulating covering around the connectors of the Clamps indoor unit and fix it with insulating tape. (page 22 (3,4) insulating covering 2. Fix the exceeding part of the signal cable to the piping or to the outdoor unit. 3.
  • Page 34 INSTALLATION MANUAL - Information for the installer WIRING DIAGRAM For different models, the wiring diagram may be different. Please refer to the wiring diagrams affixed to the indoor unit and outdoor unit respectively. On the indoor unit, the wiring diagram is l ocated under the front panel;...
  • Page 35 INSTALLATION MANUAL - Information for the installer CABLE WIRES SPECIFICATION 12K- 12K- INVERTER TYPE 115V 115V 230V 230V MODEL capacity (Btu/h) sectional area 3.0mm 3.0mm 3.0mm 3.0mm 3.0mm 3.0mm 3.0mm N(L2) AWG12 AWG12 AWG12 AWG12 AWG12 AWG12 AWG12 3.0mm 3.0mm 3.0mm 3.0mm 3.0mm...
  • Page 36: Maintenance

    INSTALLATION MANUAL - MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance, t urn the power supply off . INDOOR UNIT ANTIDUST FILTERS 1. Open the front panel (following the direction of the arrow).
  • Page 37: Troubleshooting

    INSTALLATION MANUAL - TROUBLESHOOTING MALFUNCTION POSSIBLE CAUSES Power failure/plug pulled out. Damaged indoor/outdoor unit fan motor. Faulty compressor thermomagnetic circuit breaker. Faulty protective device or fuses. The appliance does not Loose connections or plug pulled out. operate It sometimes stops operating to protect the appliance. Voltage higher or lower than the voltage range.
  • Page 38: General Notes

    GENERAL NOTES ..........................
  • Page 39 GENERAL NOTES ..........................
  • Page 40 Tel: (305) 593 - 8358 www.klimaire.com customerservice@klimaire.com The Klimaire logo is a registered Trademark of Klimaire Products Inc. Copyright 2020 Klimaire Products Inc. The design and specifi cations are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.