Fuse Replacement - Motomaster Eliminator Product Manual

300 w mobile power outlet
Hide thumbs Also See for Eliminator:
Table of Contents

Advertisement

23

Fuse replacement

For continued protection against risk of fire or electric shock, replace only with a fuse of the same
type and ratings (12 V, 8 A).
Follow the instructions to replace the fuse inside the cigarette lighter plug of your connector cable (J):
Unscrew the upper cover of the cigarette lighter plug.
Remove the faulty fuse.
Insert a new fuse and screw the cover of the plug back on.
011-1870-6-Mobile-Power-Outlet_300W-EN-07.indd 23-24
WARNING!
FAULTy FUSE
NEW FUSE
The inverter is equipped with protective shutdown features and an acoustic signal.
The details are listed in the following table:
ALARM
POSSIBLE CAUSE
As the battery discharges, its
voltage decreases. Voltage drops
Low battery
to: 10.5–11.0 V = alarm.
alarm and
Voltage drops to:
low-voltage
10.0–10.5 V = shutdown.
shutdown
This protects the battery from
being over-discharged.
A defective battery charging
system can cause the battery
voltage to rise to high levels
High-
(15.0–16.3 V).
voltage
Although the inverter has a
shutdown
protection against high voltage,
it might still be damaged if the
input voltage were to exceed 16 V.
If you connect a device that is
Overload
rated too high or a load that draws
shutdown
excessive surge power, the power
inverter shuts down.
The power inverter shuts down
Overheat
automatically if it exceeds its safe
shutdown
operating temperature.
ERROR
SOLUTION
SIGNAL
Shut down sensitive loads such as
Audible
computers and then recharge the
alarm
battery.
Red
indicator
Recharge the battery.
light (g)
turns on
disconnect the connected devices.
Red
Verify that the charging system is
indicator
properly regulated and the battery is
light (g)
12 V nominal.
turns on
Red
Use a product with a power rating
indicator
within the inverter's continuous
light (g)
power rating ( Operation).
turns on
• Switch the inverter off and
disconnect it from the cigarette
lighter socket.
• disconnect all connected devices
Red
and allow the inverter to cool for
indicator
at least 15 minutes.
light (g)
• Use a brush to clear any blocked
turns on
ventilation holes.
• move the inverter to a cooler
place. Reduce the load if
continuous operation is required.