Paxton Easyprox 30100 Manual

Compact keypad

Advertisement

Quick Links

03/01/2017
Ins-30100 Easyprox compact keypad
Technical Support
01273 811011
Technical help is available:
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Layout
For use on internal low traffic doors, typically up to 50 uses per day.
Parts list
1
1
2
3
4
5
6
7
8
9
*
0
#
13
Tools List
Power Drill
Drill bits 10 mm, 25 mm
Philips screwdriver
Hacksaw for cutting bolts
Hammer / Mallet
Chisel 25 mm
2
6
7
8
9
14
support@paxton.co.uk
Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
3
4
5
10
11
12
Stanley knife
Adhesive tape
Pencil
Tape measure
8 mm spanner (supplied)
2 mm Allen key (supplied)
1) Front Lock Assembly
2) Rear Lock Assembly
3) Rubber Escutcheon x2
4) Left and Right Handles
5) Battery Pack
6) Tubular Mortice Lock
7) Spindle
8) 8 mm Conversion Sleeve
9) 2 mm Allen Key
10) 8 mm Spanner
11) Strike Plate Backbox
12) Strike Plate
13) Long Mounting Screws x4
14) Short Mounting Screws x4
Paxton
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Paxton Easyprox 30100

  • Page 1 Monday - Friday from 07:00 - 19:00 (GMT) Saturday from 09:00 - 13:00 (GMT) Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/ Layout For use on internal low traffic doors, typically up to 50 uses per day.
  • Page 2: Installing The Hardware

    Installing the hardware Step 1 - Marking out Decide on the lock height and mark this on the door. Fold the template along one dotted line and tape it to the door with the 'Centreline of Latch' at the required height. Mark the 4 x 10 mm and 1 x 25 mm holes.
  • Page 3: Step 6 - Fitting The Handles

    Step 5 - Mounting on the door Select the short (doors thinner than 45 mm) or long mounting screws and cut to length if required. (door thickness + 5 mm) Fit the rubber escutcheons to the front and back plates. Present the front and rear lock assembly to the door, locating the square drive in its recess and join the two parts together with 4 mounting screws.
  • Page 4 INITIALISING A NEW SYSTEM Choose a 6 digit Programming Code and load this into the unit as follows: DO NOT USE 123456 - The default User Code (1234) will open the door before the Programming Code had been fully entered. 6 digit 6 digit Programming Programming Code...
  • Page 5 PROXIMITY with TOUCHLOCK mode (i) The unit must first be initialised in TOUCHLOCK mode: See TOUCHLOCK section (ii) Set up the required operating mode, as follows: Enter 6 digit Programming Code Card plus PIN Card plus Code Card or Code Hold for 3 secs (iii) Present enrolment card Enrolment card...
  • Page 6 Enrolment Card - must be presented when the system is first powered on 1. At installation, present this card to the reader to validate the tokens in this pack 2. To re-validate a user token present this enrolment card to the reader followed by the user token 1.
  • Page 7: Silent Operation

    Door open time FUNCTION CARD door open time card The period that the door is unlocked for when a valid token is presented is set as follows: 1. Present this card 2. Wait for the required period 3. Present this card again, the beeping will stop 1.
  • Page 8: Commissioning Checks

    3. Remove the access plate to reveal the battery pack. - Fig 2. 4. Unplug the lead and replace the pack with a new Paxton battery pack. - Fig 3. (The unit will retain its settings and should not be manually reset).
  • Page 9 Door open time 1 sec 60 sec Access levels (Colour Zones) Silent operation Environment Operating temperature - Battery limits 0 °C 55 °C Paxton Battery Pack Battery Type Typical Battery Life 30,000 operations Waterproof Vandal resistance Read Range Token Keyfob...

This manual is also suitable for:

Easyprox compact

Table of Contents