You have purchased a product made by JUNG
PUMPEN and with it, therefore, also excel-
lent quality and service. Secure this service
by carrying out the installation works in ac-
cordance with the instructions, so that our
product can perform its task to your complete
satisfaction. Please remember that damage
caused by incorrect installation or handling
will adversely affect the guarantee.
Therefore please adhere to the instructions in
this manual!
As with all electrical devices, this product
can also fail to operate due to an interruption
in the electricity supply or due to a techni-
cal defect. If this could result in damage, a
mains-independent alarm system must be
installed. Depending on the application, you
may also wish to install an emergency power
generator, or a second system as a back-up.
SAFETY
INSTRUCTIONS
This instruction manual contains essential
information that must be observed during
installation, operation and servicing. It is
therefore important that the installer and
the responsible technician/operator read this
instruction manual before the equipment is
installed and put into operation. The manual
must always be available at the location whe-
re the pump or the plant is installed.
Failure to observe the safety instructions can
lead to the loss of all indemnity.
In this instruction manual, safety information
is distinctly labelled with particular symbols.
Disregarding this information can be dange-
rous.
General danger to people
Warning of electrical voltage
ATTENTION!
Danger to equipment and operation
Qualification and training of
personnel
All personnel involved with the operation,
servicing, inspection and installation of the
equipment must be suitably qualified for this
work and must have studied the instruction
manual in depth to ensure that they are suf-
ficiently conversant with its contents. The
supervision, competence and areas of res-
ponsibility of the personnel must be precisely
regulated by the operator. If the personnel do
not have the necessary skills, they must be
instructed and trained accordingly.
Safety-conscious working
The safety instructions in this instruction
manual, the existing national regulations
regarding accident prevention, and any inter-
nal working, operating and safety regulations
must be adhered to.
Safety instructions for the
operator/user
All legal regulations, local directives and sa-
fety regulations must be adhered to.
The possibility of danger due to electrical
energy must be prevented.
Leakages of dangerous (e.g. explosive, toxic,
hot) substances must be discharged such
that no danger to people or the environment
occurs. Legal regulations must be observed.
Safety instructions for instal-
lation, inspection and main-
tenance works
As a basic principle, works may only be car-
ried out to the equipment when it is shut
down. Pumps or plant that convey harmful
substances must be decontaminated.
All safety and protection components must
be re-fitted and/or made operational imme-
diately after the works have been completed.
Their effectiveness must be checked before
restarting, taking into account the current
regulations and stipulations.
Unauthorised modifications,
manufacture of spare parts
The equipment may only be modified or alte-
red in agreement with the manufacturer. The
use of original spare parts and accessories
approved by the manufacturer is important
for safety reasons. The use of other parts can
result in liability for consequential damage
being rescinded.
ENGLISH
Unauthorised operating me-
thods
The operational safety of the supplied equip-
ment is only guaranteed if the equipment is
used for its intended purpose. The limiting
values given in the "Technical Data" section
may not be exceeded under any circumstan-
ces.
Instructions regarding acci-
dent prevention
Before commencing servicing or maintenance
works, cordon off the working area and check
that the lifting gear is in perfect condition.
Never work alone. Always wear a hard hat,
safety glasses and safety shoes and, if nec-
essary, a suitable safety belt.
Before carrying out welding works or using
electrical devices, check to ensure there is
no danger of explosion.
People working in wastewater systems must
be vaccinated against the pathogens that
may be found there. For the sake of your
health, be sure to pay meticulous attention to
cleanliness wherever you are working.
Make sure that there are no toxic gases in the
working area.
Observe the health and safety at work regula-
tions and make sure that a first-aid kit is to
hand.
In some cases, the pump and the pumping
medium may be hot and could cause burns.
For installations in areas subject to explosion
hazards, special regulations apply!
This appliance can be used by children aged
8 years or over and by persons with limited
physical, sensory or intellectual capabilities,
or with limited experience and knowledge,
provided that they are supervised or have
been instructed in the safe use of the appli-
ance and are aware of the dangers involved.
Children must not be allowed to play with the
appliance. Cleaning and user maintenance
must not be carried out by children unless
they are supervised.
7

Advertisement

loading

Summary of Contents for Jung Pumpen US 62

  • Page 1 ENGLISH You have purchased a product made by JUNG Qualification and training of Unauthorised operating me- PUMPEN and with it, therefore, also excel- personnel thods lent quality and service. Secure this service All personnel involved with the operation, The operational safety of the supplied equip- by carrying out the installation works in ac- servicing, inspection and installation of the ment is only guaranteed if the equipment is...
  • Page 2: Electrical Connection

    US  62, US 73 380 255 US 62 to US 105 ture of 104°F (40°C) or 194°F (90°C) US  75 395 205 in the case of HE and HES hot water...
  • Page 3: Installation

    ALARM performance of the pump only insignifi- In contrast to pumps with built-in lev- cantly. US 62, US 73 > 385 el control, the ON and OFF switching US 102, US 103 295 > 415...
  • Page 4: Maintenance

    ENGLISH into the 3 markings with the ø 8 sym- Changing the oil Quick tips for remedying bols. Deburr the drill-holes. Re-attach faults To ensure operational reliability, the the cover with the round sealing ring first oil change should be carried out and the foot strainer or base feet.
  • Page 5 Technische Daten • Technical data • Caractéristiques techniques • Technische gegevens • Dati tecnici • Dane techniczne • Technické údaje • Műszaki adatok US 62 E / ES US 62 D / DS US 102 E / ES US 102 D / DS...
  • Page 6 * Beispiel: 20% = 2 min Betrieb + 8 min Pause (Zyklusdauer 10 min) * Example for 40%: 4 min. operation and 6 min. rest (Cycle duration 10 min.) * Exemple: 40% = 4 min de service et 6 min de pause (Durée du jeu 10 min) * Esempio: 20%: 2 min.
  • Page 7 US 62 bis US 105 US 151, US 251, US 253 D / DS US 151 E / ES US 152, US 153, US 155 D / DS US 152, US 153, US 155 E / ES...
  • Page 8 • 2004/108 EG (EMC) EN 55014-1:2011, EN 55014-2:2008, EN 61000-3-2:2009, EN 61000-3-3:2013 JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen - Germany - www.jung-pumpen.de DE · Wir erklären in alleiniger Verantwortung, dass das Produkt den aufgeführten Richtlinien entspricht. CZ · Prohlašujeme na svou výlučnou odpovědnost, že výrobek odpovídá jmenovaným směrnicím.
  • Page 9 • 2004/108 EG (EMC) EN 55014-1:2011, EN 55014-2:2008, EN 61000-3-2:2009, EN 61000-3-3:2013 JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen - Germany - www.jung-pumpen.de DE · Wir erklären in alleiniger Verantwortung, dass das Produkt den aufgeführten Richtlinien entspricht. CZ · Prohlašujeme na svou výlučnou odpovědnost, že výrobek odpovídá jmenovaným směrnicím.
  • Page 10 • 2004/108 EG (EMC) EN 55014-1:2011, EN 55014-2:2008, EN 61000-3-2:2009, EN 61000-3-3:2013 JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen - Germany - www.jung-pumpen.de DE · Wir erklären in alleiniger Verantwortung, dass das Produkt den aufgeführten Richtlinien entspricht. CZ · Prohlašujeme na svou výlučnou odpovědnost, že výrobek odpovídá jmenovaným směrnicím.
  • Page 11 ENGLISH 0197 0197 JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany 402.11.1504 / 403.11.1504 404.11.1504 EN 12050-2:2001 EN 12050-2:2001 Lifting plant for faecal-free wastewater Lifting plant for faecal-free wastewater US 62 E (JP09812/4) US  73 E (JP00676/12)