JUNG PUMPEN US US 62 US 102 US 152 US 73 H US 103 H US 73 US 103 US 153 US 151 US 251 US 253 US 75 US 105 US 155 Original-Betriebsanleitung Instrukcja eksploatacji Instruction Manual Návod pro provoz Instructions de service Návod na prevádzku...
ENGLISH Qualification and training of Unauthorised operating me- You have purchased a product made by JUNG personnel thods PUMPEN and with it, therefore, also excel- lent quality and service. Secure this service All personnel involved with the operation, The operational safety of the supplied equip- by carrying out the installation works in ac- servicing, inspection and installation of the ment is only guaranteed if the equipment is...
Page 3
US 62, US 73 380 255 US 62 to US 105 ture of 104°F (40°C) or 194°F (90°C) US 75 395 205 in the case of HE and HES hot water...
Page 4
ALARM performance of the pump only insignifi- In contrast to pumps with built-in lev- cantly. US 62, US 73 > 385 el control, the ON and OFF switching US 102, US 103 295 > 415...
Page 5
ENGLISH Quick tips for remedying Changing the oil into the 3 markings with the ø 8 sym- faults bols. Deburr the drill-holes. Re-attach To ensure operational reliability, the the cover with the round sealing ring first oil change should be carried out and the foot strainer or base feet.