4.2. Power Distribution Detailed Description Rear View
4.2 Figure 1: Power Distribution Rear View (Delivery State, cables are not depicted)
PART
CABLES AMP1 3 x 230V – 16A
a)
Powercon Cables for Amplifier 1 (Top Amplifier Unit).
b)
CABLES AMP2 3 x 230V – 16A
Powercon Cables for Amplifier 2 (Bottom Amplifier Unit).
Auxiliary 230V – 2 x 6A Socket
c)
AUX Power outlets for Auxiliary devices (Ethernet Switch, DSP etc.).
d)
L1/L2/L3 POWER INDICATOR LAMP
Indicators for voltage present on L1, L2 and L3.
CABLE MAIN INPUT
e)
3 PHASE 32A 5x6mm, 5 meters long double insulated cable with 5PIN 32A
3 PHASE connector for powering the Lambda Labs KW-18 Amplifier Rack.
Caution: Do not use the Powercon connectors for powering on / off the Amplifiers! The mains
POWERCON connectors are not suitable for powering up or down the system and so should not be
plugged or unplugged while under voltage!