Maintenance; Cleaning The Standing Pilot Control System - Vermont Castings DVR28IN Installation Instructions And Homeowner's Manual

Intercontinental collection direct vent gas fireplace
Table of Contents

Advertisement

Vermont Castings DVR28 Direct Vent Gas Fireplace
Burner and Burner Compartment
It is important to keep the burner and the burner
compartment clean. At least once per year the burner
compartment should be vacuumed and wiped out.
Cleaning the Standing
Pilot Control System
The burner and control system consists of
burner tube
pilot assembly
gas valve
gas orifice
Most of these components may require only an oc-
casional checkup and cleaning and some may require
adjustment. If repair is necessary, it should be per-
formed by a qualified technician.
Fireplace May Be HOT!!
1. Turn off pilot light at remote wall switch.
2. Let fireplace cool if it has been running.
3. Remove window frame assembly. (Refer to Window
Frame Assembly Removal section)
4. Vacuum burner compartment especially around
orifice primary air openings.
5. Visually inspect pilot. Brush or blow away any dust
or lint accumulation.
6. Ignite pilot - Refer to Lighting Instructions.
7. Reinstall window frame assembly.
24

Maintenance

To obtain proper operation, it is imperative that the pilot
and burner's flame characteristics are steady, not lifting
or floating.
Typically, the top 3/8" or 1/2" of the thermopile should
be engulfed in the pilot flame. (Fig. 42)
To adjust pilot burner; (by qualified service technician)
1. Remove pilot adjustment cap.
2. Adjust pilot screw to provide properly sized flame.
3. Replace pilot adjustment cap.
The primary air shutter is set at the factory and should
only be adjusted, if necessary, by a qualified service
technician.
Fig. 42 Correct pilot flame appearance.
FP1778
������
��� �����
����