Gas Specifications; Preparation; Gas Line Installation - Vermont Castings RFS22 Installation Instructions & Homeowner's Manual

Free-standing fireplaces
Table of Contents

Advertisement

GAS SPECIFICATIONS

MODEL
FUEL
RFS22RN
Natural Gas
RFS22RP
Propane Gas
RFS22TN
Natural Gas
RFS22TP
Propane Gas
RFS32RN
Natural Gas
RFS32RP
Propane Gas Millivolt Hi/Lo
RFS32TN
Natural Gas
RFS32TP
Propane Gas
RFS42RN
Natural Gas
RFS42RP
Propane Gas
RFS42TN
Natural Gas
RFS42TP
Propane Gas
The installation of your Majestic Fireplace
must conform with local codes, or in the
absence of local codes, with National Fuel
Gas Code, ANSI Z223.1 latest edition, or CAN
1 B1-149.1 and .2 Installation Code.
(EXCEPTION: Do not derate this appliance
for elevations up to 4,500 ft. (1,370mm).
Maintain the manifold pressure at 3.5 inches
W.C. for Natural Gas and 10 inches W.C. for
LP gas.)
RFS22 / RFS32 / RFS42
CERTIFIED TO
ANSI.Z21.88a-1998 / CSA 2.33a - M98
Vented Gas Fireplace Heaters
GAS INLET & MANIFOLD PRESSURES
Input Minimum
Input Maximum
Manifold Pressure

PREPARATION

The use of wall paper adjacent to this fire-
place is not recommended, as the high heat
given off by this fireplace may adversely
effect the binders in the adhesive used to
apply the wallpaper.
Before beginning, remove the glass door from the fireplace
(See page 9). Also check to make sure there is no hidden
damage to the fireplace. Take a minute and plan out the
gas, vent and electrical supply.
MAX.
MIN.
INPUT
INPUT
GAS CONTROL B.T.U.H
B.T.U.H.
Millivolt Hi/Lo
30,000
21,000
Millivolt Hi/Lo
30,000
22,500
Thermostatic
30,000
21,000
Thermostatic
30,000
22,500
Millivolt Hi/Lo
30,000
21,000
30,000
22,500
Thermostatic
30,000
21,000
Thermostatic
30,000
22,500
Millivolt Hi/Lo
40,000
28,000
Millivolt Hi/Lo
37,000
27,750
Thermostatic
40,000
28,000
Thermostatic
37,000
27,750
NATURAL
LP (Propane)
11" wc
4.5" wc
13" wc
7" wc
3.5" wc
10" wc

GAS LINE INSTALLATION

When purging gas line, the front glass must
be removed.
The gas pipeline can be brought in through the rear of the
fireplace as well as the bottom. Knockouts are provided on
the bottom behind the valve to allow for the gas pipe
installation and testing of any gas connection. It is most
convenient to bring the gas line in from the rear right
side of the valve, as this allows fan installation or
removal without disconnecting the gas line.
The gas line connection can be made with
properly tinned 3/8" copper tubing, 3/8" rigid
pipe or an approved flex connector. Since
some municipalities have some additional
local codes, it is always best to consult your
local authority and the CAN/CGA- B149 (.1 or
.2) installation code.
FOR U.S.A Installations
Fuel Gas Code, ANSI Z223.1
ways check for gas leaks with a mild soap and
Al
water solution. Do not use an open flame for
leak testing.
The gas control is equipped with a captured
screw type pressure test point, therefore it is not
necessary to provide a 1/8" test point up stream
of the control.
1/2" GAS SUPPLY
1/2" X 3/8" REDUCER
3/8" NIPPLE
3/8" X 3/8" SHUT OFF VALVE
Fig. 2
Typical gas supply installation
When using copper or flex connector use only approved
fittings. Always provide a union when using black iron
pipe so that gas line can be easily disconnected for burner
or fan servicing. See Fig. 2. See gas specification for
pressure details and ratings.
The fireplace valve must not be subjected to any test
pressures exceeding 1/2 psi. Isolate or disconnect this or
any other gas appliance control from the gas line when
pressure testing.
DO NOT USE THIS FIREPLACE IF ANY PART
OF THIS FIREPLACE HAS BEEN UNDER
WATER. IMMEDIATELY CALL A QUALIFIED
SERVICE TECHNICIAN TO INSPECT THE
HEATER AND TO REPLACE ANY PART
CONTROL WHICH HAS BEEN UNDER
WATER.
- 5 -
consult the current National
3/8" NIPPLE
3/8" UNION
3/8" NIPPLE