This instruction manual is intended for all the users of the The intended use of the unit is the improvement of indoor Enervent ventilation units. Only qualified professionals air quality, and its primary function is ventilation. may install the equipment described in this manual in The unit is also used for the recovery of heat energy accordance with the manufacturer’s instructions and the...
When you have switched off the power to the unit, wait for two (2) minutes before starting the IP 20 www.enervent.com maintenance work. Even though the power is switched off, the fans continue running and the post-heating coil remains hot for a while.
USING THE VENTILATION UNIT When the ventilation system has been carefully designed and installed, it requires only little maintenance by the user. The user can just relax and enjoy the good ventilation. Button/display Description Mode display Current operation mode Temperature display Supply air target temperature Mode button Operation mode selection...
Page 7
Away mode (1) NOTE: You can reduce ventilation when you are going to be If the Boosted mode is controlled with an external away for an extended period of time, e.g., due to a trip. button, the mode will remain on as long as the Setting: button is activated.
Page 8
Returning to the Home mode: NOTE: for 3 seconds. First, the text oFF Press button The heater does not heat the supply air if the will be displayed for a short period of time. Then outdoor temperature exceeds +25°C. the display will return to the standard view. NOTE: Eco mode The default duration of the Fireplace mode is 10...
If the structure of the ventilation system needs to be significant amount of energy. updated, contact the designer of the system. • Only use spare parts approved by Enervent. • Only use original filters. They have been designed to ensure the best possible performance of your ventilation system.
ADDITIONAL FUNCTIONS SETTINGS Supply air is too warm Maintenance reminder display If the air coming from the ventilation system is too warm: The purpose of the maintenance reminder is to remind the user when the maintenance interval has elapsed. The Go to a lower supply air target temperature by maintenance interval is 4 or 6 months depending on the pressing button...
Ventilation is insufficient Indoor air is too humid If the ventilation is insufficient: In addition to feeling the air humidity, you may also identify a too high a humidity level by listening to the 1. Check that the filters are clean and do not need to be replaced.
When you are performing maintenance work on a part of the equipment, always check the cleanliness and degree of wear of the other parts, as well. Watch the maintenance instruction video in the Help Center on our website at www.enervent. com.
Page 13
Filter replacement, right-handed ilmanvaihtolaite ventilation unit TYYPPI/TYPE: SALLA EWIND E RIGHT W/ V/ HZ / A: SRJ. NRO/SERIAL NO: IP 20 www.enervent.com Operating and maintenance instructions for the ventilation unit...
Page 14
Filter replacement, left-handed ilmanvaihtolaite ventilation unit TYYPPI/TYPE: SALLA EWIND E LEFT W/ V/ HZ / A: SRJ. NRO/SERIAL NO: IP 20 www.enervent.com...
ADDING WATER TO THE WATER TRAP (DRAINAGE OF THE CONDENSATION WATER) Left-handed model FOR YOUR INFORMATION If the K900010010 water trap is used, no water needs to be added. Right-handed model Operating and maintenance instructions for the ventilation unit...
The alarm is company authorised by the automatically reset manufacturer. when the fault is cleared. Other fault codes : Please contact an authorised maintenance company (see (Err, ----, oFFE, AL1, AL3, AL4, AL5, AL6, AL7, AL8, AL9) enervent.com/fi/contact-information/service-partners/).
Page 17
Operating and maintenance instructions for the ventilation unit...
Page 19
Operating and maintenance instructions for the ventilation unit...
‘F-PL’ will be displayed. The F-PL is not in use if a range hood has been connected to the equipment. Enervent Zehnder Oy Kipinätie 1 FI-06150 Porvoo, Finland Tel. +358 207 528 800 Fax +358 207 528 844 enervent@enervent.com...
Need help?
Do you have a question about the Salla eWind and is the answer not in the manual?
Questions and answers