8.1.9 Anomalies
Any problem related to the thermocouple will display EEE error on the panel. This could
mean that the thermocouple is damaged, disconnected or in any way unable to give a
correct temperature reading.
Should the oven exceed his maximum temperature range, the error HHH will be displayed
on the console. Turn off the burner and let the oven rest for some time, until it gets back to
its normal operational temperature range.
8.1.10 Display units
Temperature reading can be displayed either in C° or F°. To switch from a unit to the other
press SET button for 3 seconds while the oven is turned off and in standby (3 dots visible
on the display).
After 3 seconds the actually set unit will be displayed, it is possible to cycle through units
using + or – button. Last selection will be automatically stored.
Whenever the display unit is changed, the previously recorded AUt
temperature value will be reset to its default value (482F° or 250C°).
A new set procedure like described in chapter 8.1.7 will be necessary to
record the desired value again.