2.3 RF address setting

Each RF Remote Controller has an address, the address range is
1~65534.
You can set up to four "receiving address" in each RF receiver,
correspondingly, so the RF receiver can receive control commands
from maximum four matched RF Remote Controllers.
Fig. 4 RF remote controller's address setting
Fig. 5 RF receiver's address setting

2.4 Firmware Upgrade

To upgrade the Remoter Controller, you need to connect it to PC via
USB. Double click to open Mobile devices "CRP DISABLD" in "my
computer", then use the new ".Bin" file to replace the existing
"firmware.bin". after that, reset the Remote controller to make your
upgrading effective.
Select

2.5 Universal code

The Remote Controller has built-in HDL defined IR codes, which can be
used to control all HDL panels, no need to learn IR code.
"DLP panel" page can't control other panel except DLP panel.
we can use the "1 Col panel" page to control 1 Col panel, 2 Col panel,
touch panels and even LCD panels, and those IR codes we call it
Universal codes
MTIRW IR/RF Remote Controller
RF remote controller's address
Fig. 6 Upgrade firmware