Symbols used ► Instruction Important note Non-compliance can result in malfunctions or interference. 1 Safety instructions • Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. • The unit conforms to the relevant regulations and EC directives.
Page 3
► Select either the ¼“-28 UNF / M8 (2) or the ¼“-28 UNF (3) threaded adapter and insert into the unit (1). Both adapters are supplied. ► Tighten using a 3 mm Allen key. Tightening torque 8 Nm. ► Drill and tap a hole at the mounting location: - M8 hole / depth min.
Page 4
5 Scale drawing M12 x1 1/4''-28 UNF 1: threaded adapter ¼“-28 UNF / M8 2: threaded adapter ¼“-28 UNF tightening torque 8 Nm 6 Maintenance, repair, disposal The operation of the unit is maintenance-free. It is not possible to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations.
Page 5
Compact diagnosis system shall be connected only by R/C (CYJV2) cord type ADOxH04xxxxxxxxx04 or VDOxH04xxxxxxxxx04STxx040xxx, manufactured by ifm electronic, rated min. 32 V, 80 °C, available upon request from ifm electronic or use any alternate R/C (CYJV2) cord, having the same or better ratings, suitable for field wiring.