1 Preliminary note 1.1 Explanation of symbols ► Instruction > Reaction, result […] Designation of keys, buttons or indications → Cross-reference Important note Non-compliance can result in malfunction or interference� 2 Safety instructions • Please read this document prior to set-up of the unit� Ensure that the product is suitable for your application without any restrictions�...
4 Function • The unit converts the measured signal into a temperature-proportional analo- gue signal: 4���20 mA if [OU2] = [I] or 20���4 mA if [OU2] = [Ineg]� • The analogue signal can be scaled. On delivery → 11 Factory setting. • The unit supports IO-Link� 4.1 Analogue function Current output 4���20 mA Maximum setting Measuring range scaled In the set measuring range the output signal is between 4 and 20 mA�...
5 Installation ► Connect the unit to the process using a fixing element (Triclamp, adapter)� For G½" sealing cone (type TD25xx): tightening torque 30���50 Nm� 6 Electrical connection The unit must be connected by a qualified electrician� The national and international regulations for the installation of electrical equipment must be adhered to�...
7 Operating and display elements 1: Current temperature in °C 2: Current temperature in °F 3: 7-segment LED display (4 digits) 8 Parameter setting Using an IO-Link capable parameter setting tool, the following options are availa- ble: - Reading current process values� - Reading, changing and saving current parameter settings and transmitting them to other units of the same type�...
Zero-point calibration� Setting range: ± 10 K in steps of 0�1 K� The internal measured value "0" is shifted by this value� Behaviour of the output in case of an internal fault� - [ON] = the analogue signal goes to the upper end stop value (21�1 mA)�...
10 Technical data 10.1 Temperature resistance [min] [°C] Maximum operation time depending on the medium temperature Further technical data and scale drawing at www. ifm.com → Data sheet search → Enter the article number. 11 Factory setting Factory setting User setting → Technical data at www.ifm.com → Technical data at www.ifm.com → Technical data at www.ifm.com More information at www�ifm�com...
Need help?
Do you have a question about the Efector 600 TD Series and is the answer not in the manual?
Questions and answers