desired combination (minimum 1, maximum 9 digits).
Press the  button twice. If the procedure was performed
correctly, the keypad emits 3 buzzes.
I6I
Enter within 30 seconds the SECOND
Press button "T".
desired combination (minimum 1, maximum 9 digits).
Press the  button twice. If the procedure was performed
correctly, the keypad emits 3 buzzes.
PLEASE NOTE – Additional functions programmable in
the "Easy" mode are described in Chapter 8.
7 - PROCEDURES FOR PROGRAMMING
THE DEVICE IN THE "PROFESSIONAL"
MODE
7.1 (Professional)
nation to be paired with the  button (reference
digit: 1).
I1I
Enter the programming password. – Press the  button
I2I
Enter the digit "1". – Press the  button to
to confirm.
confirm.
I3I
Enter the desired combination. – Press the  but-
ton to confirm.
I4I
Enter the same combination again. – Press
the  button to confirm.
7.2 (Professional)
nation to be paired with the  button (reference
digit: 2).
I1I
Enter the programming password. – Press the  button
5 – English
I4I
Wait 5 seconds.
Programming one combi-
Programming one combi-
I3I
to confirm.
I2I
Enter the digit "2". – Press the  button to
confirm.
I3I
Enter the desired combination. – Press the  but-
I5I
ton to confirm.
I4I
Enter the same combination again. – Press
the  button to confirm.
I7I
7.3 (Professional)
bination to be paired with the  and  buttons
(reference digits: 1-2).
I1I
Enter the programming password. – Press the  button to
I2I
Enter the digits "1-2". – Press the  button to
confirm.
I3I
confirm.
Enter the desired combination. – Press the  but-
I4I
ton to confirm.
Enter the same combination again. – Press
the  button to confirm.
7.4 (Professional)
for programming the Professional mode (refer-
ence digit: 3).
The password can be modified whenever desired (the default
password is: 0-3-3-3-3-3-3). To modify the password it is
necessary to know the last valid password.
I1I
Enter the programming password. – Press the  button to
confirm.
I2I
Enter the digit "3". – Press the  button to con-
firm.
I3I
Enter a new password for programming the "Profes-
sional" mode, using seven digits chosen personally. – Press
the  button to confirm.
(i.e. the one just created). – Press the  button to confirm.
Programming one com-
Changing the Password
I4I
Enter the same password again