Fujitsu AS G07LUCA Series Service Instruction page 113

Universal floor/celling slim duct/mini duct compact cassette compact wall mounted/floor wall mounted type, inverter multi, refrigerant r410a, indoor/outdoor unit
Hide thumbs Also See for AS G07LUCA Series:
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 2
Compressor
Test 1 : Check Connection
Check terminal connection of Compressor
(loose or incorrect wiring)
V(S)
(WHITE)
Main PCB
U(R)
(RED)
Test 2 : Check Winding Resistance
Check winding resistance of each terminal
If the resistance value is 0
U(R)
W (T)
Test 3 : Replace Main PCB
If the symptom does not change with above Check 1, 2, replace Main PCB.
(SERVICE PARTS INFORMATION 10)
W (T)
(BLACK)
or infinite, replace Compressor.
V(S)
Resistance Value : 0.642
02-68
Check terminal connection of Main PCB
(loose or incorrect wiring)
Main PCB
TM403
TM404
RED
Compressor
+ 8% (20°C)
-
TM405
BLACK
WHITE

Hide quick links: