FEATURE MODEL AS G18LFCA AS G24LFCA AS G30LFCA AO G24LFL AO G18LFC AO G30LFT FEATURES ALL DC High efficiency layout Large air flow and quiet DC fan motor operation by new air flow path fan motor compressor More compact compared with conventional model New 3-row heat exchange system (24TYPE)
Page 5
Power diffuser Adoption of large power diffuser “Strong vertical air flow” provides powerful floor level heating. 12 (m) Outside air conditions:2 C 60% Operation contents: Heating, Set temperature (Max set temp) ( C) Power diffuser C, Air flow Hi, (full open) Vertical flap : Downward Horizontal flap : Center “Healthy horizontal air flow”...
Page 6
Air conditioner filter features Ion Deodorization Filter Apple-catechin Filter Organic coating fin used heat exchanger Pre Filter Antibacterial deodorizing pre-filter with special ceramic powder Long-life Ion Apple- Deodorization Filter catechin Filter Economy operation Example : Cooling operation ● Economy operation is energy saving, as the set temperature of indoor unit is shifted Economy operation by 1°C and the maximum electric value of...
WIRELESS REMOTE CONTROLLER FEATURES ● Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible. ● Can be used jointly with wired remote controllers . ● Easy to change custom code (4 patterns). Built-in timers Select from four different timer programs (On / Off / Program / Sleep). Program timer The program timer operates the ON and OFF timer once within a 24 hour period.
Page 8
FUNCTIONS MODE button Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. custom code change. (Max 4 types) 10°C HEAT button SET TEMP. button ( ▲ / ▼ ) Set remote controller custom code buttons Sets the indoor temp./ Sets R.C. custom code. ECONOMY button SLEEP button Pressed to select sleep timer.
SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS G18LFCA AS G24LFCA AS G30LFCA Power source 230V~ 50Hz Available voltage range 198-264V ~ 50Hz 5.20 7.10 8.00 Rated BTU/h 17,700 24,200 27,300 Cooling 0.9~6.0 0.9-8.0 2.9-9.0 Min.-Max. BTU/h 3,100~20,500 3,100-27,300 9,900-30,700 Capacity...
DIMENSIONS MODEL : AS G18LF, AS G24LF, AS G30LF (Unit : mm) Unit center 18 x 11 hole 26 x 11 hole 26 x 11 hole 21 x 5: 14holes 18 x 11 hole 5 x 18: 14holes ø 80 hole ø...
Page 11
INSTALLATION PLACE (Unit : mm) Outline of unit 52 or more 53 or more 80 or more 120 or more 1500 or more - (01 - 08) -...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High MODEL : AS G18LF Operation mode : FAN Voltage : 230V Unit : m/s Top view Vertical flap : Up Horizontal flap : Center Unit : m/s Top view Vertical flap : Up Horizontal flap : Right &...
Page 16
Note: Fan speed : High MODEL : AS G24LF, AS G30LF Operation mode : FAN Voltage : 230V Unit : m/s Top view Vertical flap : Up Horizontal flap : Center Unit : m/s Top view Vertical flap : Up Horizontal flap : Right &...
7-2. AIR FLOW MODEL : AS G18LF Cooling / Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1220 1020 QUIET - (01 - 14) -...
Page 18
MODEL : AS G24LF Cooling Number of Fan speed rotations Air flow (r.p.m.) 1100 HIGH 1430 1220 1020 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) 1120 HIGH 1480 1220 1020 QUIET - (01 - 15) -...
Page 19
MODEL : AS G30LF Cooling Number of Fan speed rotations Air flow (r.p.m.) 1100 HIGH 1430 1220 1020 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) 1150 HIGH 1530 1220 1020 QUIET - (01 - 16) -...
ELECTRIC CHARACTERISTICS Model name G18LF G24LF G30LF Voltage 230 ~ Power supply Frequency Max. operating current Connection cable 1.5 - 2.5 *1)Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 20) -...
SAFETY DEVICES Model Protection form AS G18LF, AS G24LF, AS G30LF Circuit protection Current fuse (PCB) 3.15A 250V Terminal protection Current (thermal) fuse 3A 250V °C OFF Fan motor protection Thermal protector program °C ON - (01 - 21) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN14 Control input See external input/output settings CN16 Operation status output for details. 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 26
● When function setting is "Forced stop" mode Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) Parts name Model name External connect kit UTY-XWZX Wire (External input) : UTY-XWZX - (01 - 23) -...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply *10 m Signal Field supply * Make the distance from the PC board to the connected unit within 10m. Relay spec.
FUNCTION SETTING 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING”...
Page 29
FUNCTION DETAILS Functions Wall mounted 1) Filter sign 2) Cooler room temperature correction 3) Heater room temperature correction 4) Auto restart Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting for the filter sign display interval in the table below according to the amount of dust or debris in the room.
Page 30
4) Auto restart Enable or disable automatic system restart after a power outage. ( ... Factory setting) Setting description Function number Setting value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
Page 31
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS Exterior Parts name Model No. Summary SU MO TU WE TH FR SA Wired remote 3 6 9 12 15 18 21 Unit control is performed by UTY-RNNYM controller wired remote controller. Fine dust, invisible mold spores, and harmful microorganisms are absorbed Apple-catechin onto the filter by static...
Page 33
2. OUTDOOR UNIT SINGLE TYPE : AO G18LFC AO G24LFL AO G30LFT DTR_AO080E_01 2011.02.07...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO G18LFC AO G24LFL AO G30LFT Power source 230V~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current 10.9 Cooling 2,150 2,340 3,600 Airflow rate Heating 2,070 2,570 3,600 Type × Q'ty Propeller fan×1 Motor output Cooling Sound pressure level...
DIMENSIONS MODEL : AO G18LF (Unit : mm) Drain port Ø20 Pitch of bolts for installation INSTALLATION PLACE (Unit : mm) 100 or more 100 or more 200 or more If the space is larger that is stated, the condition will be the same as that are no obstacles. - (02 - 02) -...
Page 37
MODEL : AO G24LF (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides. the back, side(s), and top.
Page 38
MODEL : AO G30LF (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides. the back, side(s), and top.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE MODEL : AO G18LF Pipe length (m) COOLING 0.869 0.867 Indoor unit is upper 0.973 0.911 0.885 0.883 than outdoor unit. 0.992 0.981 0.919 0.893 0.891 Height difference H 1.000 0.989 0.927 0.901 0.899...
Page 46
MODEL : AO G24LF Pipe length (m) COOLING 0.952 0.951 0.951 0.980 0.966 0.968 0.967 0.966 Indoor unit is upper than 0.988 0.984 0.970 0.972 0.971 0.970 outdoor unit. 0.995 0.992 0.988 0.974 0.976 0.975 0.974 Height difference H 1.003 1.000 0.996 0.982...
Page 47
MODEL : AO G30LF Pipe length (m) COOLING 0.932 0.929 0.924 0.945 0.947 0.945 0.940 Indoor unit is 0.984 0.961 0.963 0.960 0.956 upper than 0.988 0.988 0.965 0.967 0.964 0.959 outdoor unit. 0.990 0.992 0.992 0.968 0.971 0.968 0.963 Height difference H 0.998...
ADDITIONAL CHARGE CALCULATION MODEL : AO G18LF Refrigerant type R410A Refrigerant amount 1200 Refrigerant charge Total pipe length 15 or less 25(MAX) 20g/m Additional charge MODEL : AO G24LF Refrigerant type R410A Refrigerant amount 1650 Refrigerant charge Total pipe length 15 or less 30(MAX) 20g/m...
AIR FLOW MODEL : AO G18LF Cooling Number of rotations Air flow (r.p.m.) 2150 1265 Heating Number of rotations Air flow (r.p.m.) 2070 1218 MODEL : AO G24LF Cooling Number of rotations Air flow (r.p.m.) 2470 1050 1454 Heating Number of rotations Air flow (r.p.m.)
Page 50
MODEL : AO G30LF Cooling Number of rotations Air flow (r.p.m.) 3600 1000 2119 Heating Number of rotations Air flow (r.p.m.) 3600 1000 2119 - (02 - 16) -...
ELECTRIC CHARACTERISTICS Model name AO G18LF AO G24LF AO G30LF Voltage 230V ~ Power supply Frequency *1) Max operating current 12.5 18.5 19.0 Starting Current 10.9 Main Fuse (Circuit breaker) Current *2) Wiring spec. Power Cable 3.5-4.0 3.5-4.5 *3) Limited wiring length *1) The maximum current is the total current of indoor unit and outdoor unit.