Dimensional Data And Dimensions - Centrosolar S-Class Integration Deluxe Series Installation Manual

Table of Contents

Advertisement

Installation guide
2.4 Dimensional data and dimensions
Module type
S-Class Integration Deluxe
Module dimensions
W x H in mm
Installation dimen-
sions
Wi x Hi in mm
Horiz. installation
tolerance
∆Wi in mm
Vert. installation toler-
ance
∆Hi in mm
The calculation of the generator field dimensions should
be used as a planning aid. The total PV system dimen-
sions serve to determine the footprint of the PV generator
in the roof. The calculated and the actual dimensions may
differ, as the installation tolerances were not taken into
consideration here.
Total generator dimensions without roofing frame:
Width
=
+ 19
where S = number of modules side by side
Height
Ho in mm
=
where R = number of modules on top of the other
Total generator dimensions with roofing frame:
Width in mm
Height in mm
Number n and length L of module lathing (38 x 58 mm):
n = ( 2 x S ) + 1
[items]
L = Ho - 20
[mm]
Abbreviations:
W
Module width
H
Module height
Wi
Module installation width
Hi
Module installation height
S-Class Integration
1682 x 864
1663 x 833
± 2.0
± 1.0
Wo in mm
S x Wi
R x Hi
+ 90
Wm = Wo + 300
Hm = Ho + 670
∆Wi
Horiz. installation tolerance
∆Hi
Vert. installation tolerance
Wo
Generator width without roofing frame:
Ho
Generator height without roofing frame:
Wm
Generator width with roofing frame:
Hm
Generator height with roofing frame:
S
Number of modules side by side
R
Number of modules on top of the other
n
Number of module laths
L
Length of module laths
All dimensions are in millimeter [mm]!
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents