Installation Of The Modules - Centrosolar S-Class Integration Deluxe Series Installation Manual

Table of Contents

Advertisement

Installation guide
5.2 Installation of the modules
12
180-200 mm
a
20 mm
Figure 1
In order to screw fasten the roof lath (a) for the
lower roof connection, a lath thickness corre-
sponding to the existing roof lathing must be
used. The distance between the upper edge of
the roof tile and the lower edge of the roof lath
should be 180-200 mm. The roof lath end must
be located outside the PV generator and placed
on rafters.
Figure 2
To fasten the roof connection, use 4.5 x 35 Spax
screws. The right hand and the left hand edge
should overlap the PV generator field by ap-
prox. 250 mm. The overlapping onto the roof
tiles should be approx. 80-100 mm (overlapping
joints of roof connection approx. 100 mm for
new rolls).
Figure 3
Measure the location of the first module lath
with the frame bracket on the right exterior side.
Vertical position: 20 mm overlapping on addi-
tional roof lath (see above).
Use 5 x 10 Spax screws (not supplied) for fas-
tening.