Removal procedure
Table of Contents

Advertisement

PCBs
Step
3. Remove the control PCB.
1
Unfasten the hook at
the back and remove
the shield plate.
2
Remove the screw of
the terminal board.
3
Pull out the terminals
and remove the
terminal board.
4
Cut the clamp.
5
Release the earth/
ground wire and indoor
heat exchanger
thermistor harnesses
from the 2 hooks.
6
Unfasten the 3 hooks
and remove the control
PCB.
18
Procedure
r
Shield plate
Terminal board
(R20013)
Clamp
Hook
(R20014)
Control PCB
Hook
(R23808)
Si041401EB
Points
Hook
Removal Procedure