Si041401EB
Step
6
Pull out the 2 terminals
of the limit switch.
7
Remove the 2 screws,
and then the limit
switch.
8
Remove the screw of
the reduction motor.
9
Slightly tilt the reduction
motor downward and
rotate to the left to
remove it.
Removal Procedure
Procedure
Terminal
Reduction
motor
Limit Switch / Reduction Motor
Limit switch
(R19994)
(R19995)
(R19996)
Points