Download Print this page
jablotron JA-164J Quick Manual

jablotron JA-164J Quick Manual

One-way four-button keyfob

Advertisement

Quick Links

The JA-164J One-way four-button keyfob
The JA-164J is a component of the
JABLOTRON 100 system. It uses one
way communication. It is designed to
remotely control a security system,
various
appliances
(using
programmable outputs PG) or to trigger
panic alarms. The remote control can
also be enrolled to multipurpose relays
such as the AC-16x series for direct
relay control according to the pre-set
mode. The remote is equipped with
optical and acoustic indication. It checks
its battery status and indicates when the
battery is nearly discharged.
Figure: 1 – LED indication; A, B, C, D – buttons, see their functions according to
Enrolling the remote control to a control
panel
There must be a JA-11xR radio module installed in the control panel
for the ability to work with a control panel. The remote can be enrolled
to an arbitrary number of JABLOTRON 100 systems and one pair of
buttons can control multiple sections in the system (common control).
It occupies one position in the system.
1. Control panel has to be in service mode.
2. Basic procedure:
a. Go to the F-Link software, select the required position in the
Devices tab and launch enrollment mode.
b. For the transmission of an enrollment signal press and hold buttons
(A+B) simultaneously for at least 3 s (within this time the red LED
flashes rapidly).
c.
After 3 s the enrollment signal is sent and confirmed by one long
LED flash. Release both buttons and close enrollment mode.
To set the keyfob to comply with security
grade 2 use F-Link SW, Parameters tab and
the option "Perform EN50131-1". (See the
JA-10xK control panel installation manual)
Notes:
Enrolling the remote control to the system is possible by entering
the production code via F-Link software. The production code is on
the sticker with a bar code glued onto the battery holder inside the
remote.
All
digits
in
the
(1400-00-0000-0001).
If you want to remove the remote control from the system (for
instance when someone has lost it), erase it from the particular
address of the control panel.
Setting the properties
Perform settings using F-Link software – Devices tab. Click on the
JA-164J´s Internal settings. Then a window appears automatically
where you can set the following parameters:
Functions of the buttons: set a particular function for the pair of
buttons A-B or C-D (setting / unsetting typically, ON / OFF switching of
some appliance, etc.) or a function for each single button A, B, C, D
(gate opening, garage door opening, etc.) and a double press of the
A+B or C+D buttons, i.e. the next button on the remote. For an option
overview see table 1.
Reaction for single buttons
/
/
/
(A/B/C/D)
None (button not used)
Copy PG
Change PG state
Silent panic **)
Audible panic **)
Health troubles
Report A, B, C, D
Reaction for pair of buttons (segment function)
-
/
Unset / Set
Unset / Partially set
Unset / Partially set / Set
PG OFF / PG ON
Table: 1. Button function options overview
The JA-164J One-way four button keyfob
PG
table 1.
production
code
are
required
Reaction for pressing
simultaneously
+
/
+
(A+B/C+D)
None (button not used)
Copy PG *)
Change PG state
Silent panic **)
Audible panic **)
Health troubles
Report A, B, C, D
-
(A-B/C-D)
For each function selected for a remote control button it is necessary
to select the appropriate PG or sections to be controlled or from which
reports should be sent (panic, etc.). For the common control of multiple
sections it is not recommended to operate a common section, but to
select the desired section in the remote control internal settings.
Notes:
*)
The „Copy PG" reaction to a double press can be used for a 1 s
impulse only for the selected PG – double button pressing cannot
send a 1s activation signal repeatedly unlike single buttons.
**) The reactions of the buttons which are not supported when the
system is configured to comply with security grade 2.
The option "Do not set with active zone", doesn´t allow the system
to be set using a remote control (keyfob) when any zone with an
Instant reaction is active. To set the system all zones / detectors
have to be in standby
When the button on the remote control is pressed permanently
(valid for the "Copy PG" function) activation is sent continuously
every 1 s. The function can be used for the extension of the impulse
of a PG output (the chosen PG output has to be set to the function
"Copy"). The maximum length of keeping up the activation is
1 minute
Take over a user´s access privileges: Take over a user's access
privileges for the sections and time limited access according to the
specific user.
Take over a user's identity: The selected user will be visible as
a source in the event log.
Operation with a multipurpose relay (MPR)
The remote control can also be enrolled to a multipurpose relay of the
AC-16x series, to control a relay according to the chosen mode. Each
button should be enrolled to the MPR with a different mode. Even one
remote can be enrolled to multiple MPRs for example with a different
function. When you enroll a keyfob to the control panel and also to an
MPR within its RF range, don´t select the same buttons. To enroll
a keyfob to an MPR, follow the installation manual of the MPR.
Locking the keyfob
The remote control buttons can be locked (blocked) against
accidental pressing. Locking is disabled by default, pressing any button
triggers its function immediately. If the buttons are locked, a control
panel command is sent when a button is pressed 2x quickly (2x per 1 s)
it is also valid for the panic function.
The lock can be activated by pressing and holding the pair of
buttons (A+B) at the same time. After pressing both buttons the red
LED (1) flashes 1x and subsequently after 3 s the red LED starts
flashing quickly, during LED flashing release button B and then press it
again. Activation of the lock function is performed and confirmed by
double flashes of the red LED and a double beep. After this
confirmation release all buttons.
The lock is deactivated by repeating the procedure above.
Deactivation of locking is confirmed by one flash of the red LED and
one beep.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
door control), it is necessary to mind that the action is
performed first.
Acoustic indication
Acoustic indication can be completely disabled. The default is
enabled. When any button is pressed it is followed by a short acoustic
signal according to the table 2.
The acoustic indication can be disabled by simultaneous pressing
and holding the pair of buttons (A+B) until the red LED (1) starts
flashing briefly for the second time, usually in 6 s. When the red LED (1)
flashes a second time release the button (B) and press it again. The
acoustic indication is then disabled and confirmed by flashes of the red
LED and a one beep. After this confirmation release all buttons.
The acoustic indication can be enabled by repeating the procedure
above. Activation is confirmed by a double flash of the red LED and a
double beep.
Caution:
When
a
reaction
simultaneously is set (for example a panic alarm or garage door
control), it is necessary to mind that the action is performed first.
1 / 2
for
pressing
buttons
(A+B)
MMJ58104

Advertisement

loading

Summary of Contents for jablotron JA-164J

  • Page 1 The remote can be enrolled 1 minute to an arbitrary number of JABLOTRON 100 systems and one pair of buttons can control multiple sections in the system (common control). Take over a user´s access privileges: Take over a user’s access It occupies one position in the system.
  • Page 2 The remote still works as usual but the RF range goes slowly down. Low battery indication is cancelled when a new battery is JABLOTRON ALARMS a.s. hereby declares that the JA-164J is in inserted. a compliance with the relevant Union harmonisation legislation: To change the battery, unscrew the 2 screws from the back plastic;...