jablotron JA-152J MS Quick Start Manual

Bi-directional two-button keyfob

Advertisement

Quick Links

The JA-152J MS Bi-directional two-button keyfob
The JA-152J MS is a component of
the JABLOTRON 100 system. It uses
bi-directional
communication.
designed to remotely control a security
system, various appliances (using PG
programmable outputs) or to trigger
panic alarms and more. The remote
control
can
also
be
enrolled
multipurpose relays such as the AC-16x
series for direct relay control according
to the pre-set mode. The remote is
equipped with optical and acoustic
indication. It checks its battery status
and indicates when the battery is nearly discharged.
Figure: 1 – LED indication; A, B – buttons, see their functions according to
Enrolling the remote control to a control panel
There must be a JA-11xR radio module installed in the control panel for
the ability to work with a control panel. It occupies one position in the system.
The
remote
can
be
enrolled
JABLOTRON 100 systems. One pair of buttons can control several
sections at the same time (common control) and it can show the current
status of the section or PG output.
1.
The control panel has to be in service mode.
2.
Basic procedure:
a.
Go to the F-Link software, select the required position in the
Devices tab and launch enrollment mode.
b.
For transmission of an enrollment signal press and hold buttons
(A+B) simultaneously for at least 3 s (within this time the yellow
LED flashes rapidly).
c.
After 3 s the enrollment signal is sent and confirmed by one long
yellow LED flash. Release both buttons and close enrollment
mode.
To set the keyfob to comply with security
grade 2 use F-Link SW, Parameters tab and
the option "Perform EN50131-1". (See the
JA-10xK control panel installation manual)
Notes:
Enrolling the remote control to the system is possible by entering
the production code via F-Link software. The production code is on
the sticker with a bar code glued onto the battery holder inside the
remote.
All
digits
in
the
(example: 1400-00-0000-0001)
If you want to remove the remote control from the system (for
instance when someone has lost it), erase it from the particular
address of the control panel.
Setting the properties
Perform settings using F-Link software – Devices tab. Click on the
JA-152J´s Internal settings. Then a window appears automatically
where you can set the following parameters:
Functions of the buttons: set a particular function for the pair of
buttons A-B (typically setting / unsetting, OFF / ON switching of some
appliance, etc.) or a function for each single button A, B (gate opening,
garage door opening, etc.) and also for a double press of the remote.
See the following table 1.
Reaction for single button
/
(A / B)
None (button not used)
Copy PG
Change PG state
Silent panic ***)
Audible panic ***)
Health troubles
Report A, B, C, D
Reaction for pair of buttons (segment function)
-
Unset / Set
Unset / Partially set
Unset / Partially set / Set
Unset / Set with confirmation
Unset / Partially set with confirmation
Unset / Partially set / Set with confirmation
PG OFF / ON
Table 1. Button function options overview
The JA-152J MS Bi-directional two-button keyfob
It
is
to
table 1.
to
an
arbitrary
number
production
code
are
required
Reaction for pressing
simultaneously
+
(A + B)
None (button not used)
Read status *)
Copy PG **)
Change PG status
Silent panic ***)
Audible panic ***)
Health troubles
Report A, B, C, D
(A - B)
For each function selected for a remote control button it is necessary
to select the appropriate PG or sections to be controlled or from which
reports should be reported (panic, etc.). For the common control of
multiple sections it is not recommended to operate a common section,
but to select the desired section in the remote control internal settings.
Notes:
*)
If there is a pre-set function for the pair of buttons A+B (typically
Unset / Set section or PG OFF / ON), then that option also triggers
the option „Read status". If this option is enabled the remote
reacts to a double press by showing the current status of the
section or PG.
**) The „Copy PG" reaction to a double press can be used for a 1 s
impulse only for the selected PG – double button pressing cannot
send 1s activation signal repeatedly unlike single buttons.
***) The reactions of the buttons which are not supported when the
system is configured comply with security grade 2.
For all functions related to setting the sections, the control panel
obeys the option „Ways of setting" selected in the Parameters tab.
a.
For „with confirmation" types of setting (see table 1), for „set
with warning" options and „set with confirmation" pressing the
of
buttons in an 8 s period can be repeated and the command is
performed.
b.
The option „Do not set with active zone", doesn´t allow the
system to be set using a remote control (keyfob) when any
zone with an Instant reaction is active. To set the system all
zones / detectors have to be in standby.
When the button on the remote control is pressed permanently
(valid for the „Copy PG" function) activation is sent continuously
every 1 s. The function can be used for the extension of the impulse
of a PG output (the chosen PG output has to be set to the function
„Copy"). Maximum length of keeping the activation is 1 minute.
Take over a user´s access privileges: Taking over a user´s access
privileges for the sections and time limited access according to the
specific user, it respects individual access to the controlled section and
also limited access to a section if pre-set. Factory settings: disabled.
Take over a user´s identity: The selected user will be visible as a
source in the event log. Factory settings: disabled.
Delayed panic: Valid for reactions such as Silent panic and Audible
panic. The delay can be set from 5 to 240 s. Cancelling the panic alarm
during a running delay can be performed by repeated pressing of the
specific button.
The control panel is able to run a
maximum
(delayed panic alarms).
Operation with a multipurpose relay (MPR)
The remote control can also be enrolled to a multipurpose relay of the
AC-16x series, to control a relay according to the chosen mode. Each
button should be enrolled to the MPR with a different mode. Even one
remote can be enrolled to multiple MPRs for example with a different
function. When you enroll a keyfob to the control panel and also to an
MPR within its RF range, don´t select the same buttons. To enroll a
keyfob to an MPR, follow the installation manual of the MPR.
Locking the keyfob
The remote control buttons can be locked (blocked) against
accidental pressing. Locking is disabled by default, pressing any button
triggers its function immediately.
If the buttons are locked, a control panel command is sent when a
button is pressed 2x quickly (2x per 1 s) it is also valid for the panic
function.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
door control), it is necessary to mind that the action is
performed first.
The lock can be activated by simultaneously pressing and holding
the pair of buttons (A+B) until the yellow LED (1) starts flashing, usually
in 3 s. When the yellow LED (1) is flashing release button (B) and press
it again. Activation of the lock function is performed and confirmed by
double flashes of the yellow LED and a double beep. After this
confirmation release all buttons.
The lock is deactivated by repeating the procedure above.
Deactivation of locking is confirmed by one flash of the yellow LED and
one beep.
Acoustic indication
Acoustic indication can be completely disabled. The default is
enabled. When any button is pressed it is followed by a short acoustic
signal according to the table 2.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
1 / 2
of
5
simultaneous
timers
MMJ54102