Bi-directional two-button key fob

Advertisement

Quick Links

The JA-152J MS II Bi-directional two-button key fob
The JA-152J MS II is a component of the JABLOTRON 100 + system.
It is designed to remotely control a security system, various appliances
(using PG programmable outputs) or to trigger panic alarms and more.
The remote control can also be
enrolled to multipurpose relays such
as the AC-16x series for direct relay
control according to the pre-set
mode. The remote is equipped with
optical and acoustic indication. It
checks
its
battery
status
indicates when the battery is nearly
discharged.
The
remote
communicates via the Jablotron
wireless protocol and is powered by
a single power cell. The remote
takes up a single position in the
system.
Figure: 1 – LED indication; A, B – buttons, see their functions according to
Enrolling the remote control to a control panel
There must be a JA-11xR radio module installed in the control panel for
the ability to work with a control panel. It occupies one position in the system.
The remote can be enrolled to an arbitrary number of JABLOTRON 100
systems. One pair of buttons can control several sections at the same time
(common control) and it can show the current status of the section or PG
output.
1.
The control panel has to be in service mode.
2.
Basic procedure:
a.
Go to the F-Link software, select the required position in the
Devices tab and launch enrollment mode.
b.
For transmission of an enrollment signal press and hold buttons
(A+B) simultaneously for at least 3 s (within this time the yellow
LED flashes rapidly).
c.
After 3 s the enrollment signal is sent and confirmed by one long
yellow LED flash. Release both buttons and close enrollment
mode.
To set the key fob to comply with security
grade 2 use F-Link SW, Parameters tab and
the option "Perform EN50131-1". (See the
JA-10xK control panel installation manual)
Notes:
Enrolling the remote control to the system is possible by entering
the production code via F-Link software. The production code is on
the sticker with a bar code glued onto the battery holder inside the
remote.
All
digits
in
the
(example: 1400-00-0000-0001)
If you want to remove the remote control from the system (for
instance when someone has lost it), erase it from the particular
address of the control panel.
Setting the properties
Perform settings using F-Link software – Devices tab. Click on the
JA-152J MS II´s Internal settings. Then a window
automatically where you can set the following parameters:
Functions of the buttons: set a particular function for the pair of
buttons A-B (typically setting / unsetting, OFF / ON switching of some
appliance, etc.) or a function for each single button A, B (gate opening,
garage door opening, etc.) and also for a double press of the remote.
See the following table 1.
JA-152J MS II
and
table 1.
production
code
are
required
appears
Reaction for single button
/
(A / B)
None (button not used)
Copy PG
Change PG state
Silent panic ***)
Audible panic ***)
Health troubles
Report A, B, C, D
Reaction for pair of buttons (segment function)
Unset / Set
Unset / Partially set
Unset / Partially set / Set
Unset / Set with confirmation
Unset / Partially set with confirmation
Unset / Partially set / Set with confirmation
PG OFF / ON
Table 1. Button function options overview
For each function selected for a remote control button it is necessary
to select the appropriate PG or sections to be controlled or from which
reports should be reported (panic, etc.). For the common control
of multiple sections it is not recommended to operate a common
section, but to select the desired section in the remote control internal
settings.
Notes:
*)
Once a button (with the "Copy PG" function enabled) is pressed
and held, the activation signal is transmitted once every second.
The function can be utilized to extend the duration of a PG output
(said PG must have the "copy PG" function enabled). The aximal
length of continuous transmission is 1 minute.
**)
The „Copy PG" reaction to a double press can be used for a 1 s
impulse only for the selected PG – double button pressing cannot
send 1s activation signal repeatedly unlike single buttons.
***)
The reactions of the buttons which are not supported when the
system is configured comply with security grade 2.
****) If there is a pre-set function for the pair of buttons A+B (typically
Unset / Set section or PG OFF / ON), then that option also
triggers the option „Read status". If this option is enabled the
remote reacts to a double press by showing the current status of
the section or PG.
For all functions related to setting the sections, the control panel
follows the option „Ways of setting" selected in the Parameters tab.
a.
For „with confirmation" types of setting (see table 1), for „set
with warning" options and „set with confirmation" pressing the
buttons in an 8 s period can be repeated and the command is
performed.
b.
The option „Do not set with active zone", doesn´t allow the
system to be set using a remote control (key fob) when any
zone with an Instant reaction is active. To set the system all
zones have to be in standby.
Take over a user´s access privileges: Taking over a user´s access
privileges for the sections and time limited access according to the
specific user, it respects individual access to the controlled section and
also limited access to a section if pre-set. Factory settings: disabled.
Take over a user´s identity: The selected user will be visible as
a source in the event log. Factory settings: disabled.
Delayed panic: Valid for reactions such as Silent panic and Audible
panic. The delay can be set from 5 to 240 s. Cancelling the panic alarm
during a running delay can be performed by repeated pressing of the
specific button.
The control panel is able to run a maximum
of 5 simultaneous timers (delayed panic
alarms).
Operation with a multipurpose relay (MPR)
The remote control can also be enrolled to a multipurpose relay of the
AC-16x series, to control a relay according to the chosen mode. Each
button should be enrolled to the MPR with a different mode. Even one
remote can be enrolled to multiple MPRs for example with a different
function. When you enroll a keyfob to the control panel and also to an
MPR within its RF range, don´t select the same buttons. To enroll
a keyfob to an MPR, follow the installation manual of the MPR.
1 / 2
Reaction for pressing
simultaneously
+
(A + B)
None (button not used)
Read status ***)
Copy PG **)
Change PG status
Silent panic ***)
Audible panic ***)
Health troubles
Report A, B, C, D
-
(A - B)
MMJ23100

Advertisement

loading

Summary of Contents for jablotron JA-152J MS II

  • Page 1 The JA-152J MS II Bi-directional two-button key fob The JA-152J MS II is a component of the JABLOTRON 100 + system. Reaction for pressing Reaction for single button It is designed to remotely control a security system, various appliances simultaneously (using PG programmable outputs) or to trigger panic alarms and more.
  • Page 2 The press of a button is indicated by an acoustic signal (if set) followed by a LED flash of corresponding colour. JABLOTRON ALARMS a.s. hereby declares that the The mentioned indication statuses are valid for the remote’s default JA-152J MS II is in a compliance with the relevant Union setting. harmonisation legislation: Directives...