Maintenance - IDEAL Viceroy GT Series Installation, Assembly And Servicing

Oil or dual gas fired boilers
Table of Contents

Advertisement

9

MAINTENANCE

Boiler
It is not advisable to drain an installation, except in case of
absolute necessity. Check regularly the water level of the
installation and top it up if necessary, avoiding a sudden inlet
of cold water into the hot boiler.
This operation can only be done a few times a year;
otherwise, look for the leakage and remedy it without delay.
Cleaning of the flue gas circuit:
For this purpose:
- unhook the front cover,
- open the sweeping doors (upper doors)
by unscrewing the 3 lock nuts (19mm spanner)
- remove the baffles
- using the brush supplied, carefully sweep
the 8 flue ways
- also brush the baffles and the front face
- if possible use a vacuum cleaner
- put the baffles back in place
(pay attention to their direction)
- shut the door
Hints for maintenance
Baffles (per flue way)
Upper
1
Middle
2
Lower
3 or
4
Viceroy GT Range
- Installation
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
Identification plate
GT 8
8229-0010
then
8229-0022
8229-0011
then
8229-0023
8229-0012
then
8229-0024
The good performance of the boiler depends on its
degree of cleanliness.
Cleaning of the boiler must be carried out as often as
required and at least, as the chimney once a year or more,
according to the regulations in force. The following
operations are always carried out with the boiler and the
power supply shut off.
GT 9-10
GT 11-12
2x8229-0010
2x
then
8229-0010
1x8229-0022
2x8229-0011
2x
then
8229-0011
1x8229-0023
2x8229-0012
2x
then
8229-0012
1x8229-0024
ASSEMBLY
8229-EN-46 A
8229-EN-28
GT 13-14
3x
8229-0010
3x
8229-0011
3x
8229-0012
19