Specification Of Connection Cables (Common In Use); 1-Phase Terminal Block Spec; 3-Phase Terminal Block Spec; Ac Power : M5 Screw - Samsung AE RXEDEG Series Installation Manual

Outdoor unit, air to water heat pump
Hide thumbs Also See for AE RXEDEG Series:
Table of Contents

Advertisement

Specification of connection cables (common in use)

Power supply
1Φ, 220-240 V, 50 Hz
3Φ, 380-415 V, 50 Hz
For Power Cable, use the grade H07RN-F or H05RN-F materials.

1-phase terminal block spec

AC power : M5 screw

L
17

3-phase terminal block spec

AC power : M4 screw
L1(R)
1(L)
2(N)
L2(S)
9.8
Max/Min(V)
Power supply cords of parts of appliances for outdoor use shall not be lighter
than polychloroprene sheathed flexible cord. (Code designation IEC:60245 IEC
57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
When installing the outdoor unit in a computer room or net work room, server
room or in the presence of risk of disturbance to the communication cable,
use the double shielded (tape aluminium / polyester braid + copper ) cable of
FROHH2R type.
N
13
L3(T)
N
14.19
ENGLISH-21
±10 %
Communication : M4 screw
Communication : M4 screw
Communation cable
0.75~1.5 mm², 2 wires
10.1
10.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae rxedgg seriesAe090rxedegAe090rxedgg