Heavy Snow Fall Area (Natural Drainage) - Samsung AE RXEDEG Series Installation Manual

Outdoor unit, air to water heat pump
Hide thumbs Also See for AE RXEDEG Series:
Table of Contents

Advertisement

• Heavy snow fall area (Natural drainage)

When using the air conditioner in the heating mode, ice may accumulate. During de-icing (defrost operation), the
condensed water must be drained off safely. For the air conditioner operates well, you must follow the instructions below.
- Make space more than 80mm between the bottom of the outdoor unit and the ground for installation.
80 mm
- If the product is installed in a region of heavy snow, allow enough separation distance between the product and the
ground.
- When installing the product, make sure that the rack is not placed under the drain hole.
- Ensure that the drained water runs off correctly and safely.
• In areas with heavy snow fall, piled snow could block the air
intake. To avoid this incident, install a frame that is higher than
CAUTION
estimated snow fall. In addition, install a snow-proof hood to
avoid snow from piling on the outdoor unit.
• If ice accumulates on the base, it may cause critical damage
to the product. (e.g., a lakeside in a cold area, the seashore, an
alpine region, etc.)
• In a heavy snowfall area, do not install the drain plug and drain
cap into the outdoor unit. And, it may cause frozen ground.
Therefore, take appropriate measures to prevent it.
ENGLISH-17
Snow-proof
hood
Estimated
snow fall
Frame
Ground