System Set-Up

Common Setting

• 3 Minutes Delay
Factory use only.
• Remote sensor active
If user connects remote air sensor to control the product by room air temperature, the connection
information should be notified to the product.
Note : If remote air sensor is connected but this function code is not set correctly, the product can
not be controlled by room air temperature.
• Celsius / Fahrenheit Switching
Temperature is displayed in Celsius or Fahrenheit.
• Temp. sensor selection
The product can be operated according to air temperature or leaving water temperature. The
selection for setting temperature as air temperature or leaving water temperature is determined.
Note : Air temperature as setting temperature is ONLY available when Remote Air Sensor
Connection is enabled and Remote Air Sensor Connection is set as 02.
• Dry Contact Mode
This function allows the Dry contact-indoor unit operate under Auto Run mode or Manual mode with
remote control panel.
74 Air-to-Water Heat Pump