1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 73

Summary

• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Test
Disable 3 minute Delay
Remote sensor active
Celsius / Fahrenheit Switching
Temp. sensor selection
Dry Contact Mode
Air cooling set temp.
Water cooling set temp
Air heating set temp.
Water heating set temp
DHW set temp.
Screed drying
Heater on temperature
Water supply off temp. during cooling
min. and max. of outdoor temp. for
auto mode
min. and max. of Indoor air temp. for
auto mode
min. and max. of LWT for auto mode
Tank disinfection setting 1
Tank disinfection setting 2
Tank setting 1
Tank setting 2
Heater priority
DHW time setting
Note: Some contents may not be displayed depending on DIP switch setting in the main PCB assembly 1.
Factory use only
Connection information about remote air sensor
Display temperature in Celsius or Fahrenheit
Selection for setting temperature as air temperature or leaving water temperature
Setting dry contact auto start option.
Adjusting range of 'Setting Air Temperature' in cooling mode
Adjusting range of 'Setting Leaving Water Temperature' in cooling mode
Adjusting range of 'Setting Air Temperature' in heating mode
Adjusting range of 'Setting Heating Flow Temperature' in heating mode
Adjusting range of 'Setting DHW tank Heating Flow Temperature' in domestic hot
water tank heating mode
After installing water pipes for under floor heating, user can select screed drying
mode for curing the cement
Setting for using Step 1 or 2 capacity of electric heater
Determine leaving water temperature when the unit is turned off.
This funtion is used for preventing condensation on the floor in cooling mode
Setting outdoor Min/Max temperature for auto mode
Setting indoor Min/Max temperature for auto mode
Setting heating flow Min/Max temperature for auto mode
Setting start/maintain time for pasteurisation
Setting pasteurisation temperature
Setting start temperature for operation
Setting maintain temperature for operation
Determine electric heater and water heater on and off
Determine follow time duration : operation time of domestic hot water tank heating,
stop time of domestic hot water tank heating, and delay time of DHW tank heater
operating
System Set-Up
Description
Installation Manual 73