Page 1
162 305 09-2 14/08/2019 Providing sustainable energy solutions worldwide Installation and Maintenance CTC EcoPart 600M Modulating ground source heat pump Model 612M / 616M 400 V 3N~ IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE...
Page 2
Removing the cooling module • Any work done on the product’s cooling system should be done by authorised personnel only. • Close the safety switch before doing any work on the product. 1. Disconnect the cooling module’s power cable con- 2.
Page 3
Installation and Maintenance 162 305 09-2 14/08/2019 CTC EcoPart 600M Modell 612M / 616M 400 V 3N~...
Connection of the heat medium side _____________________________________ __________________ 7.4.3 Connection box 4.1.1 Circulation Pumps (Charging pumps) (G11) ____________________________________________ _____ Parts list 4.1.2 Pump diagram EcoPart 600M __________________________________________________________ ________________________ Connecting the cold carrier system (brine sys- Resistances for sensors ____________________________________ First start tem)
Page 5
Cleaning and maintenance should not be carried out by children without supervision. If these instructions are not followed when installing, operating and maintaining the system, Enertech’s commitment under the applicable warranty terms is not binding. CTC EcoPart 600M...
Page 6
The heat pump can be connected to the CTC EcoZenith i550 Pro or to the existing heating system via the CTC EcoLogic control system CTC EcoPart 600M has been designed to operate with high efficiency and low noise levels. Save this manual containing the installation and maintenance instructions.
Installation and maintenance manual supplied to the customer Check and filling, heating circuit Information on fine adjustments Alarm information Functional test of safety valves fitted Information on procedures for fault registration ______________________________________ ______________________________________ Date/Customer Date/Installer CTC EcoPart 600M...
• The installation engineer advises the property owner on the design and servicing of the system. • The installation engineer fills in a checklist and contact information – the customer and installation engineer sign the list, which the customer keeps. CTC EcoPart 600M...
Below are the connection options (controlling products) available for CTC EcoPart 600M. CTC EcoPart 600M (612M/616M) CTC EcoLogic Pro/Family CTC EcoZenith i550 Pro Control products must have software version (or later): CTC EcoZenith i550 Pro: 2019-06-20 CTC EcoLogic Pro/Family: 2019-08-01 CTC EcoPart 600M...
673 x 596 x 775 (depth x width x height) Noise level (L ) @ B0 and W35/55 in compl.w.EN12102 39/41 dB(A) HP Keymark Cert. No. 012-073 The products are not covered by the periodical check for leaking refrigerant. CTC EcoPart 600M...
Page 11
(depth x width x height) 673 x 596 x 775 Noise level (L ) @ B0 and W35/55 in compliance with EN12102 dB(A) 36/40 HP Keymark Cert. No. 012-SC0819-18 The products are not covered by the periodical check for leaking refrigerant. CTC EcoPart 600M...
Refer to section Dimensions sketch for measurements and dimensions. The pipe dimension between the heat pump and brine loop should be not less than Ø28 mm. Edging strips (x2), supplied Brine out Brine in CTC EcoPart 600M...
104) with the bifurcation so that you can later fill and bleed the collector circuit. 5.1.2 Insulation against condensation All pipes in the brine system must be insulated against condensation to prevent the possibility of severe build-up of ice and condensation dripping. CTC EcoPart 600M...
When refitting, the pin under the filter holder should be fed into the designated hole in the filter housing. Top up with a little brine, if necessary, before fitting the cap. The filter should be checked and cleaned after a short period of operation. CTC EcoPart 600M...
The installation should be preceded by an omnipolar safety switch according to overvoltage category III, which ensures disconnection from all electric power sources. The EcoPart 600M should be equipped with a faulty residual current switch with delayed deactivation. 6.1.2 Alarm output The CTC EcoPart 600M is fitted with a potential-free alarm output which...
The communication cable of the heat pump (LiYCY (TP)) is connected directly to the respective controlling product. When installing only one heat pump, make sure that DIP switch 2 is in the ON position (pre-set factory value). CTC EcoPart 600M...
When connecting more than one heat pump, the heat pumps (A1, A2, A3... Controlling products: etc) must be addressed. All CTC EcoPart 600M are factory-set addressed to A1. Chapter Connection control shows how addressing is done from the -CTC EcoLogic Pro can display of the controlling product.
Brine pump on 10 days * In this example, we have assumed that the heat pump Select /Rename Heatpump is called A1, which is the factory default. If the heat pump has already been renumbered, then select this number instead. CTC EcoPart 600M...
Page 25
A1 and then A2 up to A10 to ensure that the correct name is given. Finally test in the menu "Advanced/Service/Function test/Heat pump" that the respective heat pump starts. CTC EcoPart 600M...
Sensor Type 2 Sensor Type 3 Sensor Type 1 NTC 015 Temperature °C Temperature°C Temperature °C Temperature °C Resistance kΩ Resistance kΩ Resistance kΩ Resistance kΩ 0.67 5.37 0.22 0.76 0.78 6.18 0.25 0.86 0.908 7.13 0.28 0.97 1.06 8.26 0.32 1.11 1.25...
• The products do not require annual inspection for refrigerant leakage. 9.2 Operation stop The heat pump is shut down using the operating switch. If there is a risk of the water freezing, drain off all the water from the CTC EcoPart 600M. CTC EcoPart 600M...
10. Troubleshooting/appropriate measures The CTC EcoPart 600M is designed to provide reliable operation and high levels of comfort, as well as a long service life. If a fault occurs, you should always contact the installer who installed your unit. If the installer believes the malfunction is due to a materials or design fault, then they will contact Enertech AB to check and rectify the issue.