162 105 97-2 2018-01-09 Providing sustainable energy solutions worldwide Installation- and Maintenance Manual CTC EcoAir 510M Modulating air/water heat pump 400 V 3N~ IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE...
Page 3
Installation and Maintenance Manual CTC EcoAir 510M Modulating air/water heat pump 400 V 3N~...
If these instructions are not followed when installing, operating and maintaining the system, Enertech’s commitment under the applicable warranty terms is not binding. Information in this type of box [!] is particularly important for correctly installing and using the product. CTC EcoAir 510M 400V 3N~...
Page 6
The Complete System CTC EcoAir 510M Control CTC EcoAir 510M is a modulating air source heat pump CTC EcoAir 520M is controlled by these products. that takes heat from the outside air and supplies it to the • CTC EcoZenith i250 existing heating system in the house. The heat pump •...
Check and filling, heating system Information on fine adjustments Alarm information Functional test of safety valves fitted Information on procedures for fault registration ______________________________________ ______________________________________ Date / Customer Date / Installer CTC EcoAir 510M 400V 3N~...
* The sound specified should be regarded as an indication since the level is affected by the compressor’s and the fan’s speed, as well as the surroundings. The upper value corresponds to 100% reflecting ground and walls (smooth concrete). CTC EcoAir 510M 400V 3N~...
17. Expansion valve Heating mode Defrosting mode Operating range The control system for the CTC EcoAir 510M monitors and ensures that the product is working within its operating range. Primary flow Cº Outside temperature Cº CTC EcoAir 510M 400V 3N~...
Page 13
Component location CTC EcoAir 510M EMI fi lter 16. Primary l ow sensor 17. Bleeding nipple/water Frequency converter 18. Expansion valve Defrosting sensor in evaporator 19. Connection box Type plate with serial number etc. 20. Communication Compressor 21. Hot gas sensor High pressure switch 22.
Positioning • Place the product on a solid foundation. • The CTC EcoAir 510M has a factory-fitted condensation water tray where the condensation water is conducted to a stone curb, surface water gully, down pipe or other drainage. You should therefore consider the position of the product.
The installation must be carried out in accordance with current MCS standards. Refer to MIS 3005 and associated building regs Part L,F & G. Delivery includes • 1 x Heat pump CTC EcoAir 510M • 15 m cable LiYCY (TP 2x2x0,75 mm ) with connector for communication, fitted.
Placement of the heat pump • CTC EcoAir 510M is normally placed against an outside wall. >0.25 m • The CTC EcoAir 510M has a factory-fitted condensation water tray >0.25 m >1 m where the condensation water is conducted to a stone curb, surface water gully, down pipe or other drainage.
• Use a spirit level to ensure that the blocks are level. • Place crushed stones around the blocks to achieve optimal drainage. 451 mm 1155 mm dimension Moisture barrier, moisture barrier, up against the building Concrete blocks foundations. Coarse crushed stone about 70-100 cm deep. CTC EcoAir 510M 400V 3N~...
• A heating cable (available as an accessory) should be placed in the pipe to prevent refreezing. The heating cable is connected to the electrical cabinet in the CTC EcoAir 510M. (Must be performed by an authorised electrician and according to applicable provisions.) •...
• The product can be bled via the bleed valve inside the condenser. NOTE! Only bleed this valve. Other valves are for the cooling system! If these are opened, refrigerant may leak out! CTC EcoAir 510M 400V 3N~...
The heat pump’s lower connection must be connected to the charge pump so that water is pumped out to the heat pump. The heat pump’s upper connection is connected to the right diverting valve by the charge pump. CTC EcoAir 510M 400V 3N~...
760 l/tim must be maintained. This provides about: 7 °C temperature differential with an outside temperature of +7 °C and a primary flow temperature of 35 °C at minimum flow 0.21 l/s. Pressure differential diagram CTC EcoAir 510M Pressure differential (kPa) Water low (l/s)
5.1.1 Electrical installation 400 V 3N~ The CTC EcoAir 510M must be connected to 400 V 3N~ 50 Hz and protective earth. The 2 m long power supply cable is pre-connected to the product.
Once the system has heated up, check that all connections are tight, the various systems have been bled, heat is coming out into the system and warm water is coming out at the tap locations. CTC EcoAir 510M 400V 3N~...
Defrosting The CTC EcoAir 510M is fitted with hot gas defrosting. The heat pump checks constantly whether defrosting is needed and, if so, defrosting starts, the fan stops, the four-way valve changes direction and the hot gas goes to the evaporator instead.
Page 30
As an accessory you can buy a heating cable to connect to EcoAir. The cable is fitted in the drain from the condensation tray to the frost-free drain. Condensation tray and drain CTC EcoAir 510M 400V 3N~...
8. Troubleshooting/appropriate measures The CTC EcoAir 510M is designed to provide reliable operation and high levels of comfort, and to have a long service life. Various tips are given below which may be helpful and guide you in the event of an operational malfunction.
Page 32
162 105 97-2 2018-01-09 Enertech AB. PO Box 309 SE-341 26 Ljungby Sweden. www.ctc.se, www.ctc-heating.com...