Deluxe Upper Board: Engineering Guide
ENG 5: SPEED SENSOR MODE
Press
. The belt will begin to move. The PWM value is displayed in the upper right window. The Elevation
"START"
A/D is displayed in the upper left window. The Dot Matrix displays a flashing row of lights between 2 constant rows
of lights. As the
"SPEED UP"
ENG 6: STUCK KEY TEST
Press any key on the overlay and, if functioning properly, that key will display.
ENG 7: EXIT ENGINEERING
ERROR MESSAGES
Three types of errors can occur; speed, elevation, and EEPROM software error. All three use the same display to indicate
the error, with the error number appearing in the main window. An elevation error shuts down the treadmill and disables
normal operation. A speed sensor error also shuts down the treadmill. The user, however, can enter engineering mode
after an error announcement.
ERROR

DISPLAY DESCRIPTION

Elevation
E4
Current elevation position is outside
Range
zero and max elevation values
Elevation
E4
Current elevation position has not
Stall
reached target incline
Elevation
E6
No elevation signal reading or elevation
Lost
motor is not connected.
Over speed
E7
Speed of the belt differs from the
calibrated max speed by 1.0 mph or
km/h as measured by the speed sensor
No Speed
E9
Speed sensor has not been
Feedback
connected or malfunction
No
E10
MCB does not receive a signal for
Communication
3 seconds
SAFETY SWITCH
If the safety magnet disconnects from the console, the treadmill shuts down if in run mode. The treadmill displays " " - - - - - - - - " " in
the main window. This is a safety precaution to warn the user that power is still being applied to the board. This safety
switch condition occurs in any mode, including engineering modes.
When the magnet reconnects to the console, the board resets. Any activity or run time information prior to the reconnection
will be lost.
TREADMILL.ENG.TM356.REV2
arrow is pressed the flashing row will flash quicker, indicating a faster PWM.
37
SOLUTION
Enter ENG 1 and manually position elevation within
the min and max values. If not possible, recalibrate
min and max elevation
Check for bad cable connection. Check for connection
between motor controller and elevation motor as well
as any obstruction to the elevation. Try to reboot system
Check for bad cable connection. Check for connection
between motor controller and elevation motor. Check
for bad elevation motor
Cycle power to clear error. Check speed sensor and
magnets as well as any obstruction to the rollers or
running belt. Recalibrate.
Check speed sensor connection on lower board
Check connection between upper and lower control
boards
Date of last revision: 10.08