Thank you for purchasing CAS SWΙΙ PLUS series. These series have been designed with CAS reliability, under rigid quality control and with outstanding performance. Your special departments can enjoy these high quality reliable CAS products. We believe that your needs will be satisfied and you will have proper reliability.
Page 6
DISPLAY & KEYBOARD KEY FUNCTIONS KEYS FUNCTIONS Used to set the zero point. Used to convert the unit of weight. (If you press the button long time, Unit is converted) Used to input or cancel the weight of tare. Used to make the weight of commodity stable. This weight is average value.
● Turn on the scale by pressing key. Then, the display will show all the segments and count up "0" to "9". You may stop this automatic counting by pressing the key. When you turn on the display, make sure that platter is empty. Otherwise, ●...
② Press the key. ③ Place a commodity into the container, then the display will show only the weight of the commodity. ④ Remove container and commodity, then the display will show the weight of the container with "-" symbol. ⑤...
5. Comparator Function - HI / LOW Limit Setting ① Press the key until the display shows "WL OFF" (Press the key for a few second). "WL OFF" means that comparator function is not activated.. ② Press key to activate this function. The display shows "WL ON".
⑧If you want to go back to the simple weighing mode just press key twice. (Press the key for a few second). ⑨Suppose that the HIGH limit and LOW limit are set up as 2.990kg and 1,990kg respectively. If the weight loaded is 2kg between HIGH and LOW limit the display shows "OK"...
Page 11
⑥ Remove all of commodities from the scale. ● Counting with Tare ① Press key twice to go to sample unit selection mode. "PCS" is shown on the display, then press key to select the number of sample unit. ② Put the container on the scale and press key to set weight of tare.You can select 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 200, 300, 400 or 500 as a sample unit, by pressing...
Page 12
⑦ Press "Tare" key to exit from tare function. ⑧ When you try to set the number of sample unit at the ③ stage, the display may show "LACK" message shortly. The result of counting may be incorrect in the following cases.
7. Setup Mode Make sure that power is OFF. While pressing the key, press the key. The display shows “U SEt”. You can select each menu by pressing the key and change the setting by pressing the key. If you press key, you can save current setting and go next mode.
Remove unstable facts. stable. The "Err 1" occurs when a current zero point has shifted from the last Please call your CAS dealer. span calibration. The "Err 3" is an overload error. Please remove the weight. The "Err 9" is no weight error. When...
MODEL : SWΙΙ-W Dual Dual Dual Dual Single Single Single Single Interval Interval Interval Interval Capacity 1.5/3 kg 3 kg 3/6 kg 6 kg 6/15 kg 15 kg 15/30 kg 30 kg e=0.5/1 g e=1 g e=1/2 g e=2 g e=2/5 g e=5 g e=5/10 g...