Digital gauge
Table of Contents

Advertisement

Available languages

Available languages

When using a power supply with remote sensing function
Line driver
SIG
SIG
*SIG
AM26C31
Outputs: A/B phase
Point a
+V
+S
_S
0 V
When using a power supply without remote sensing function
Line driver
SIG
SIG
*SIG
AM26C31
Outputs: A/B phase
*
+V
+S
_S
0 V
* When using DG805BLM/DG810BM/DG810BLM, the main unit
input should be at +5 V ± 5%.
12
(E)
50 m or less
AWG26 or thicker
twisted pair cable
30 m or less
AWG20 or thicker
twisted pair cable
AWG20 or more
Receiving device
Line receiver:
AM26C32 or
equivalent product
120
AM26C32
+V
+S
_S
0 V
Receiving device
Line receiver:
AM26C32 or
equivalent product
120
AM26C32
+V
0 V