Technical Specifications
Materials
Steel
Connections
1/2" flow and return, underneath connections
Test Pressure
6 Bar
Testing Authority
EN442
Maximum operating pressure
4 Bar
o
Maximum working temperature
95
C
Packaging
Polystyrene protection in cardboard box
PLEASE NOTE: Systems using micro bore pipework must have adequate pressure and flow rates
for the number and style of radiators on the system.
Terms & Conditions
All products must be inspected once removed from the packaging and The Radiator Company notified
within 28 days of delivery of any scratches, blemishes or other damage.
The Radiator Company will then replace the radiator.
Imperfect radiators should therefore not be fitted and The Radiator Company will not accept
responsibility for replacement of scratched or damaged radiators once they have been fitted. This
includes any consequential loss or cost of fitting.
If The Radiator Company are not notified within 28 days of the date on the signed delivery note then it
will be deemed that The Radiator Company have fully complied with its obligations and claims will not
be considered.
Failure to comply with any of the above may invalidate any claims.
We recommend that after you check the product on delivery that it is stored in its packaging to
prevent damage prior to installation. The Radiator Company cannot accept responsibility for items
damaged after delivery.
Guarantees & Liabilities
As we are not the manufacturers of this product we will take all reasonable endeavours to make over to
you the benefit of any warranty or guarantee given by the manufacturer, which is usually five years on
most of our range. (Copies of specific guarantees for any of our products are available on request).
The guarantees in all cases are subject to the products being installed in accordance with British and or
European standards as well as these fitting instructions. The guarantees in all cases are restricted to the
free of charge replacement or repair of the failed product only. Our liability will under no circumstances
extend beyond the repair or replacement of the product supplied by us. Claims for either labour in
replacement or damage to property are not admissible. Any goods that are returned, in the event of a
problem, will belong to The Radiator Company.
If you have any questions please contact us: 01342 302250, www.theradiatorcompany.co.uk
THE
RADIATOR
COMPANY
Fittings Instructions
ATHEH_IR_1.0
A brand of
Athena
horizontal
Please read these instructions and terms and
conditons carefully prior to installation.
Failure to do so may invalidate the warranty
The Radiator Company
Units 13 - 14 Charlwoods Road
East Grinstead
West Sussex
RH19 2HU
, Italy's leading manufacturer of design led radiators
5

Advertisement

loading
Need help?

Need help?

Do you have a question about the THE RADIATOR COMPANY Athena and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IRSAP THE RADIATOR COMPANY Athena

  • Page 1 Technical Specifications Athena RADIATOR Materials Steel horizontal COMPANY Connections 1/2” flow and return, underneath connections Test Pressure 6 Bar Fittings Instructions Testing Authority EN442 Maximum operating pressure 4 Bar Maximum working temperature Packaging Polystyrene protection in cardboard box PLEASE NOTE: Systems using micro bore pipework must have adequate pressure and flow rates for the number and style of radiators on the system.
  • Page 2 Diagrams of Athena Horizontal Pipe Centres Fix Brackets 1. Insert bracket nipples into threaded holes on the back of Pipe centres left to right width minus 70mm the radiator. 67-75 Pipe centres from wall 45mm to 53mm 45-53 2. The fixing positions for the two top brackets are measured Depth from wall 67mm to 75mm down 77.5mm from the top of the radiator and 35mm...
  • Page 3 Technical Specifications RADIATOR Athena Vertical Materials Steel COMPANY Connections 1/2” flow and return Test Pressure 6 Bar Fittings Instructions Testing Authority EN442 Maximum operating pressure 4 Bar Maximum working temperature Packaging Polystyrene protection in cardboard box PLEASE NOTE: Systems using micro bore pipework must have adequate pressure and flow rates for  the number and style of radiators on the system. Terms &...
  • Page 4 Diagrams of Athena Vertical Pipe Centres Fix Brackets 1. Insert bracket nipples into threaded holes on the back of Pipe centres left to right width minus 70mm 67-75 the radiator. Pipe centres from wall 45mm to 53mm 45-53 2. The fixing positions for the two top brackets are measured Depth from wall 67mm to 75mm down 77.5mm from the top of the radiator and 35mm in...